PFAS in Saint-Cyr-sur-le-Rhône's tap water: 10 ng/L, 20x our 0.5 ng/L benchmark
Last PFAS check: · Source: Hub'eau
PFAS in drinking water
20× above our health benchmark
0.5 ng/L is our benchmark, not an official limit. Same EFSA method as Sweden, Denmark and the Netherlands, but stricter. It's a yearly average, compared here with the latest check.
Sample taken in Ampuis, on the same distribution network as Saint-Cyr-sur-le-Rhône (AMPUIS-ST CYR BOURG). The health authority samples one tap per network; a network carries the same treated water everywhere.
More about this result
The US also limits PFOA and PFOS to 4 ng/L each, per substance.
One of these four, PFOA, is classified as causing cancer in humans by the WHO's cancer research agency (IARC).
More PFAS than in 96% of the cities we track
checked on 22 June 2026
20 PFAS (see each substance)
| PFAS substance | Value |
|---|---|
| Acide perfluorohexanoïque (PFHXA) | 0.006 µg/L |
| Acide perfluoropentanoïque (PFPEA) | 0.006 µg/L |
| Acide sulfonique de perfluorooctane (PFOS) | 0.004 µg/L |
| Acide perfluorobutanoïque (PFBA) | 0.003 µg/L |
| Perfluorohexane sulfonate (PFHXS) | 0.002 µg/L |
| Acide sulfonique de perfluorobutane (PFBS) | 0.002 µg/L |
| Acide perfluoro-octanoïque (PFOA) | 0.002 µg/L |
| Acide perfluoroheptanoïque (PFHPA) | 0.002 µg/L |
| Acide perfluoro-nonanoïque (PFNA) | 0.002 µg/L |
| Acide perfluorododécanoique (PFDoDA) | <0,001 µg/L |
| Acide perfluorododécane sulfonique (PFDoDS) | <0,001 µg/L |
| Acide perfluorodecane sulfonique (PFDS) | <0,001 µg/L |
| Acide perfluoro tridecanoique (PFTrDA) | <0,001 µg/L |
| Acide perfluoro tridecane sulfonique (PFTrDS) | <0,005 µg/L |
| Acide perfluoro undecanoïque (PFUnA) | <0,001 µg/L |
| Acide perfluorononane sulfonique (PFNS) | <0,002 µg/L |
| Acide perfluoro undecane sulfonique (PFUnDS) | <0,002 µg/L |
| Acide perfluoroheptane sulfonique (PFHpS) | <0,002 µg/L |
| Acide perfluoro-decanoïque (PFDA) | <0,001 µg/L |
| Acide perfluoropentane sulfonique (PFPS) | <0,001 µg/L |
Above our health benchmark. Here are some filter options.
- EU legal limit
- 29 ng/L sum of 20 PFAS, below the 100 ng/L limit
- Last PFAS test
- 22 June 2026
- Water supplier
- ENTREPRISE CHOLTON
In Saint-Cyr-sur-le-Rhône, the 4 most closely watched PFAS (PFAS-4) add up to 10 ng/L (0.01 µg/L) at the latest PFAS check on 22 June 2026. That's 20 times our 0.5 ng/L health benchmark, and above Sweden's legal limit of 4 ng/L. Sum of 20 PFAS: 29 ng/L (0.029 µg/L), below the EU legal limit (100 ng/L). Sampled in Ampuis, on the same network. 8 checks since 11 September 2025: PFAS-4 from 10 ng/L to 22 ng/L, averaging 19.6 ng/L over 12 months. Rising on the main network. Source: Hub'eau, Qualité de l'eau potable (Ministère de la Santé / OFB / BRGM).
Details and sources
PFAS over time in Saint-Cyr-sur-le-Rhône
48 PFAS checks since 7 March 2023, from the published measurements. Samples from 17 communes on the same network: it's the same water, so each one applies to Saint-Cyr-sur-le-Rhône. Samples come from 2 distribution networks. The trend refers to the network “MONTS DU LYONNAIS”.
“Calculated”: PFAS-4 worked out from the four substances in the same sample. The chart, averages and trends use lab-published sums only.
| Date | PFAS-4 | Sum of 20 PFAS | Sampled at | Network |
|---|---|---|---|---|
| 10 ng/L | 29 ng/L | Ampuis | AMPUIS-ST CYR BOURG | |
| 22 ng/L | 62 ng/L | Condrieu | MONTS DU LYONNAIS | |
| 17 ng/L | 51 ng/L | Chambost-Longessaigne | MONTS DU LYONNAIS | |
| 22 ng/L | 61 ng/L | Grigny-sur-Rhône | MONTS DU LYONNAIS | |
| 14 ng/L | 36 ng/L | Ampuis | AMPUIS-ST CYR BOURG | |
| 22 ng/L | 67 ng/L | Sainte-Catherine | MONTS DU LYONNAIS | |
| 11 ng/L | 38 ng/L | Ampuis | AMPUIS-ST CYR BOURG | |
| 15 ng/L | 56 ng/L | Grigny-sur-Rhône | MONTS DU LYONNAIS | |
| 22 ng/L · calculated | 63 ng/L | Pomeys | MONTS DU LYONNAIS | |
| 9 ng/L · calculated | 30 ng/L | Ampuis | AMPUIS-ST CYR BOURG | |
| 10 ng/L · calculated | 29 ng/L | Saint-Cyr-sur-le-Rhône | AMPUIS-ST CYR BOURG | |
| 21 ng/L – < 22 ng/L · calculated | 60 ng/L | Grigny-sur-Rhône | MONTS DU LYONNAIS |
Show the 36 earlier checks (back to 7 March 2023)
| 22 ng/L – < 23 ng/L · calculated | 72 ng/L | Chaussan | MONTS DU LYONNAIS | |
| 12 ng/L · calculated | 51 ng/L | Ampuis | AMPUIS-ST CYR BOURG | |
| 12 ng/L · calculated | 35 ng/L | Ampuis | AMPUIS-ST CYR BOURG | |
| 22 ng/L – < 23 ng/L · calculated | 69 ng/L | Grigny-sur-Rhône | MONTS DU LYONNAIS | |
| 24 ng/L · calculated | 62 ng/L | Aveize | MONTS DU LYONNAIS | |
| 13 ng/L · calculated | 38 ng/L | Ampuis | AMPUIS-ST CYR BOURG | |
| 28 ng/L · calculated | 74 ng/L | Grigny-sur-Rhône | MONTS DU LYONNAIS | |
| 14 ng/L · calculated | 42 ng/L | Ampuis | AMPUIS-ST CYR BOURG | |
| 19 ng/L · calculated | 56 ng/L | Ampuis | AMPUIS-ST CYR BOURG | |
| 26 ng/L – < 27 ng/L · calculated | 78 ng/L | Montrottier | MONTS DU LYONNAIS | |
| 11 ng/L · calculated | 36 ng/L | Ampuis | AMPUIS-ST CYR BOURG | |
| 29 ng/L · calculated | 84 ng/L | Grigny-sur-Rhône | MONTS DU LYONNAIS | |
| 22 ng/L – < 23 ng/L · calculated | 64 ng/L | Sainte-Foy-l'Argentière | MONTS DU LYONNAIS | |
| 31.4 ng/L – < 33.4 ng/L · calculated | 74.8 ng/L | Grigny-sur-Rhône | MONTS DU LYONNAIS | |
| 13.5 ng/L · calculated | 45 ng/L | Ampuis | AMPUIS-ST CYR BOURG | |
| 11.7 ng/L · calculated | 37.2 ng/L | Saint-Cyr-sur-le-Rhône | AMPUIS-ST CYR BOURG | |
| 26.4 ng/L – < 27.4 ng/L · calculated | 62.7 ng/L | Brussieu | MONTS DU LYONNAIS | |
| 18.9 ng/L – < 19.9 ng/L · calculated | 51.6 ng/L | Grigny-sur-Rhône | MONTS DU LYONNAIS | |
| 18.6 ng/L · calculated | 73.2 ng/L | Ampuis | AMPUIS-ST CYR BOURG | |
| 18.8 ng/L · calculated | 72.1 ng/L | Ampuis | AMPUIS-ST CYR BOURG | |
| 21.8 ng/L – < 22.8 ng/L · calculated | 60.7 ng/L | Haute-Rivoire | MONTS DU LYONNAIS | |
| 29.5 ng/L · calculated | 62.5 ng/L | Saint-Laurent-de-Chamousset | MONTS DU LYONNAIS | |
| 13.7 ng/L · calculated | 54.3 ng/L | Ampuis | AMPUIS-ST CYR BOURG | |
| 11.5 ng/L · calculated | 48.2 ng/L | Ampuis | AMPUIS-ST CYR BOURG | |
| 13.1 ng/L – < 14.1 ng/L · calculated | 49.9 ng/L | Grigny-sur-Rhône | MONTS DU LYONNAIS | |
| 15.9 ng/L – < 16.9 ng/L · calculated | 57.8 ng/L | Larajasse | MONTS DU LYONNAIS | |
| 9.8 ng/L · calculated | 46.6 ng/L | Ampuis | AMPUIS-ST CYR BOURG | |
| 17.4 ng/L – < 18.4 ng/L · calculated | 55.3 ng/L | Grigny-sur-Rhône | MONTS DU LYONNAIS | |
| 23.8 ng/L · calculated | 66.3 ng/L | Échalas | MONTS DU LYONNAIS | |
| 10 ng/L · calculated | 57 ng/L | Saint-Cyr-sur-le-Rhône | AMPUIS-ST CYR BOURG | |
| 14.2 ng/L · calculated | 63.7 ng/L | Ampuis | AMPUIS-ST CYR BOURG | |
| 13.5 ng/L – < 14.5 ng/L · calculated | 43.7 ng/L | Grigny-sur-Rhône | MONTS DU LYONNAIS | |
| 33.7 ng/L · calculated | 58.2 ng/L | Bessenay | MONTS DU LYONNAIS | |
| 6.5 ng/L – < 16.5 ng/L · calculated | 49.2 ng/L | Ampuis | AMPUIS-ST CYR BOURG | |
| 9 ng/L – < 19 ng/L · calculated | 55 ng/L | Ampuis | AMPUIS-ST CYR BOURG | |
| 21.6 ng/L – < 31.6 ng/L · calculated | 60.5 ng/L | Grigny-sur-Rhône | MONTS DU LYONNAIS |
Calculated values: “<” is an upper bound from published thresholds, “≥” a lower bound, “–” means no published sum or complete measurement. How to read a PFAS result
What the latest check found
At the latest check, the water was within every limit tested.
See all 14 test results
| What was tested | Value | Limit | Status |
|---|---|---|---|
| Nitrate | 11.8 mg/L | ≤ 50 mg/L | within the limit |
| Nitrite | <0,01 mg/L | ≤ 0.5 mg/L | within the limit |
| Cadmium | <1 µg/L | ≤ 5 µg/L | within the limit |
| Chromium | <5 µg/L | ≤ 50 µg/L | within the limit |
| Escherichia coli | <1 n/(100mL) | ≤ 0 mL) | within the limit |
| Enterococci | <1 n/(100mL) | ≤ 0 mL) | within the limit |
| Coliform bacteria | <1 n/(100mL) | ≤ 0 mL) | within the limit |
| pH | 7.5 unité pH | 6.5–9 unité pH | within the limit |
| Water hardness | 27.04 °f | no limit | for reference |
| Electrical conductivity | 604 µS/cm | 200–1,100 µS/cm | within the limit |
| Chloride | 28.4 mg/L | ≤ 250 mg/L | within the limit |
| Sulphate | 42.7 mg/L | ≤ 250 mg/L | within the limit |
| Iron | 22 µg/L | ≤ 200 µg/L | within the limit |
| Turbidity | <0,1 NFU | ≤ 2 NFU | within the limit |
Frequently asked questions
Is tap water in Saint-Cyr-sur-le-Rhône safe to drink?
Yes. At the check on 22 June 2026, the tap water in Saint-Cyr-sur-le-Rhône was within every limit tested. “Eau d'alimentation conforme aux exigences de qualité en vigueur pour l'ensemble des paramètres mesurés.”
How high are PFAS levels in Saint-Cyr-sur-le-Rhône's drinking water?
The total of 20 PFAS ("forever chemicals") was last measured at 29 ng/L. The EU limit is 100 ng/L, so this water is at 29 % of the limit. (below the EU limit)
Does the water in Saint-Cyr-sur-le-Rhône also meet the strictest limits in Europe?
No. The four most harmful PFAS add up to 10 ng/L. That is 2.5 times Sweden's legal limit of 4 ng/L, in force since 2026. Germany will set a similar one in 2028. The water still passes the current EU legal limit (100 ng/L for the total of 20 PFAS).
Are PFAS levels rising in Saint-Cyr-sur-le-Rhône's tap water?
Yes. On the main network, the PFAS-4 sum rose from 15 ng/L (11 September 2025) to 22 ng/L (22 May 2026) across 5 quantified checks. pfasnearme's benchmark is 0.5 ng/L as an annual mean. These history statistics use laboratory-published sums only.
How hard is the water in Saint-Cyr-sur-le-Rhône?
The water hardness in Saint-Cyr-sur-le-Rhône is 27 °f (medium). This mainly matters for household appliances and detergent dosing, not for health.
Where does this data come from?
All values come from official publications: Hub'eau, Qualité de l'eau potable (Ministère de la Santé / OFB / BRGM). Retrieved on 21 September 2026.
Same water network
Same distribution network as Saint-Cyr-sur-le-Rhône, so in principle the same water.
Nearby communes
The closest to Saint-Cyr-sur-le-Rhône on this site.
Data source
- Hub'eau, Qualité de l'eau potable (Ministère de la Santé / OFB / BRGM)
- https://hubeau.eaufrance.fr/api/v1/qualite_eau_potable/resultats_dis?code_commune=69193
- License
- Licence Ouverte / Open Licence (Etalab)
- Retrieved
- 21 September 2026
- Supply networks
- MONTS DU LYONNAIS, AMPUIS-ST CYR BOURG
Water report for Saint-Cyr-sur-le-Rhône
Get new PFAS results for Saint-Cyr-sur-le-Rhône, with a short explanation. At most one update a week, only when there's something new.
This site is a data project, not an official source. If in doubt, check with your water supplier or local authority.