PFAS in Ville-le-Marclet's tap water: 4 ng/L, 8x our 0.5 ng/L benchmark

Last PFAS check: · Source: Hub'eau

PFAS in drinking water

8× above our health benchmark

Amount found in the water 4 ng/L 0.004 µg/L · the 4 most harmful PFAS (PFAS-4)
Our health benchmark 0.5 ng/L

0.5 ng/L is our benchmark, not an official limit. Same EFSA method as Sweden, Denmark and the Netherlands, but stricter. It's a yearly average, compared here with the latest check.

More about this result

The US also limits PFOA and PFOS to 4 ng/L each, per substance.

Substances below the detection limit count as 0, so the real total may be higher.

One of these four, PFOA, is classified as causing cancer in humans by the WHO's cancer research agency (IARC).

More PFAS than in 90% of the cities we track

20 PFAS (see each substance)
PFAS substance Value
Acide perfluoropentanoïque (PFPEA) 0.012 µg/L
Acide perfluorohexanoïque (PFHXA) 0.007 µg/L
Acide sulfonique de perfluorooctane (PFOS) 0.003 µg/L
Acide perfluorobutanoïque (PFBA) 0.003 µg/L
Acide perfluoroheptanoïque (PFHPA) 0.002 µg/L
Perfluorohexane sulfonate (PFHXS) 0.001 µg/L
Acide perfluoropentane sulfonique (PFPS) <0,001 µg/L
Acide perfluoro tridecanoique (PFTrDA) <0,001 µg/L
Acide perfluoroheptane sulfonique (PFHpS) <0,002 µg/L
Acide perfluoro-octanoïque (PFOA) <0,001 µg/L
Acide perfluorododécane sulfonique (PFDoDS) <0,001 µg/L
Acide perfluoro tridecane sulfonique (PFTrDS) <0,005 µg/L
Acide perfluorododécanoique (PFDoDA) <0,001 µg/L
Acide perfluorodecane sulfonique (PFDS) <0,001 µg/L
Acide perfluoro-decanoïque (PFDA) <0,001 µg/L
Acide sulfonique de perfluorobutane (PFBS) <0,001 µg/L
Acide perfluorononane sulfonique (PFNS) <0,002 µg/L
Acide perfluoro undecanoïque (PFUnA) <0,001 µg/L
Acide perfluoro-nonanoïque (PFNA) <0,001 µg/L
Acide perfluoro undecane sulfonique (PFUnDS) <0,002 µg/L

Above our health benchmark. Here are some filter options.

EU legal limit
28 ng/L sum of 20 PFAS, below the 100 ng/L limit
Last PFAS test
14 January 2026
Water supplier
SIAEP DE FLIXECOURT

In Ville-le-Marclet, the 4 most closely watched PFAS (PFAS-4) add up to 4 ng/L (0.004 µg/L) at the latest PFAS check on 14 January 2026. That's 8 times our 0.5 ng/L health benchmark, exactly at Sweden's legal limit of 4 ng/L. Sum of 20 PFAS: 28 ng/L (0.028 µg/L), below the EU legal limit (100 ng/L). 2 checks since 28 February 2025: sum of 20 PFAS from 26 ng/L to 28 ng/L. Source: Hub'eau, Qualité de l'eau potable (Ministère de la Santé / OFB / BRGM).

Details and sources
Water supplier: SIAEP DE FLIXECOURT Latest water check: 20 July 2026 Data updated on

PFAS over time in Ville-le-Marclet

2 PFAS checks since 28 February 2025, from the published measurements. Samples from 2 communes on the same network: it's the same water, so each one applies to Ville-le-Marclet.

“Calculated”: PFAS-4 worked out from the four substances in the same sample. The chart, averages and trends use lab-published sums only.

28 ng/L028 February 202514 January 2026
Laboratory-published sum of 20 PFAS per check in ng/L. Hollow dots: below the detection limit. Calculated PFAS-4 values are listed in the table.
DatePFAS-4Sum of 20 PFASSampled at
4 ng/L28 ng/LVille-le-Marclet
4 ng/L – < 6 ng/L · calculated26 ng/LFlixecourt

Calculated values: “<” is an upper bound from published thresholds, “≥” a lower bound, “–” means no published sum or complete measurement. How to read a PFAS result

What the latest check found

At the latest check, the water was within every limit tested.

Microbiology: within the limit Chemistry: within the limit

Values to watch

These results are close to their legal limit, or over it.

What was tested Value Limit Status
Nitrate 25.2 mg/L ≤ 50 mg/L within the limit
See all 21 test results
What was tested Value Limit Status
Nitrate 25.2 mg/L ≤ 50 mg/L within the limit
Nitrite <0,010 mg/L ≤ 0.1 mg/L within the limit
Lead <0,5 µg/L ≤ 10 µg/L within the limit
Copper 0.011 mg(Cu)/L ≤ 2 mg(Cu)/L within the limit
Nickel 1 µg/L ≤ 20 µg/L within the limit
Arsenic <0,5 µg/L ≤ 10 µg/L within the limit
Cadmium <0,5 µg/L ≤ 5 µg/L within the limit
Chromium <0,5 µg/L ≤ 50 µg/L within the limit
Uranium <10 µg/L ≤ 30 µg/L within the limit
Fluoride 0.155 mg/L ≤ 1.5 mg/L within the limit
Escherichia coli 0 n/(100mL) ≤ 0 mL) within the limit
Enterococci 0 n/(100mL) ≤ 0 mL) within the limit
Coliform bacteria 0 n/(100mL) ≤ 0 mL) within the limit
pH 7.2 unité pH 6.5–9 unité pH within the limit
Water hardness 20.6 °f no limit for reference
Electrical conductivity 475 µS/cm 200–1,100 µS/cm within the limit
Chloride 18.7 mg/L ≤ 250 mg/L within the limit
Sulphate 7.5 mg/L ≤ 250 mg/L within the limit
Sodium 10.4 mg/L ≤ 200 mg/L within the limit
Iron <5 µg/L ≤ 200 µg/L within the limit
Turbidity <0,30 NFU ≤ 2 NFU within the limit

Frequently asked questions

Is tap water in Ville-le-Marclet safe to drink?

Yes. At the check on 20 July 2026, the tap water in Ville-le-Marclet was within every limit tested. “Eau d'alimentation conforme aux exigences de qualité en vigueur pour l'ensemble des paramètres mesurés.”

How high are PFAS levels in Ville-le-Marclet's drinking water?

The total of 20 PFAS ("forever chemicals") was last measured at 28 ng/L. The EU limit is 100 ng/L, so this water is at 28 % of the limit. (below the EU limit)

Does the water in Ville-le-Marclet also meet the strictest limits in Europe?

Yes. Even against Europe's strictest legal limit, Sweden's 4 ng/L in force since 2026, the measured value of 4 ng/L stays below.

Are PFAS levels rising in Ville-le-Marclet's tap water?

Calculated PFAS-4 values are listed in the table. The chart uses laboratory-published sum-of-20 results; there are too few laboratory-published PFAS-4 sums for the existing trend calculation.

How hard is the water in Ville-le-Marclet?

The water hardness in Ville-le-Marclet is 20.6 °f (medium). This mainly matters for household appliances and detergent dosing, not for health.

Where does this data come from?

All values come from official publications: Hub'eau, Qualité de l'eau potable (Ministère de la Santé / OFB / BRGM). Retrieved on 21 September 2026.

Same water network

Same distribution network as Ville-le-Marclet, so in principle the same water.

Nearby communes

The closest to Ville-le-Marclet on this site.

Data source

Hub'eau, Qualité de l'eau potable (Ministère de la Santé / OFB / BRGM)
https://hubeau.eaufrance.fr/api/v1/qualite_eau_potable/resultats_dis?code_commune=80795
License
Licence Ouverte / Open Licence (Etalab)
Retrieved
21 September 2026
Supply networks
FLIXECOURT UDI

This site is a data project, not an official source. If in doubt, check with your water supplier or local authority.