PFAS in Vignot's tap water: 22 ng/L, 44x our 0.5 ng/L benchmark

Last PFAS check: · Source: Hub'eau

PFAS in drinking water

44× above our health benchmark

Amount found in the water 22 ng/L 0.022 µg/L · the 4 most harmful PFAS (PFAS-4)
Our health benchmark 0.5 ng/L

0.5 ng/L is our benchmark, not an official limit. Same EFSA method as Sweden, Denmark and the Netherlands, but stricter. It's a yearly average, compared here with the latest check.

More about this result

The US also limits PFOA and PFOS to 4 ng/L each, per substance.

Substances below the detection limit count as 0, so the real total may be higher.

One of these four, PFOA, is classified as causing cancer in humans by the WHO's cancer research agency (IARC).

More PFAS than in 99% of the cities we track

20 PFAS (see each substance)
PFAS substance Value
Perfluorohexane sulfonate (PFHXS) 0.008 µg/L
Acide sulfonique de perfluorooctane (PFOS) 0.008 µg/L
Acide perfluoro-octanoïque (PFOA) 0.006 µg/L
Acide perfluoroheptanoïque (PFHPA) 0.003 µg/L
Acide sulfonique de perfluorobutane (PFBS) 0.002 µg/L
Acide perfluoro tridecanoique (PFTrDA) <0,002 µg/L
Acide perfluoro-decanoïque (PFDA) <0,002 µg/L
Acide perfluoropentane sulfonique (PFPS) <0,002 µg/L
Acide perfluorododécanoique (PFDoDA) <0,002 µg/L
Acide perfluorododécane sulfonique (PFDoDS) <0,002 µg/L
Acide perfluoro-nonanoïque (PFNA) <0,002 µg/L
Acide perfluorodecane sulfonique (PFDS) <0,002 µg/L
Acide perfluoro tridecane sulfonique (PFTrDS) <0,005 µg/L
Acide perfluoro undecane sulfonique (PFUnDS) <0,002 µg/L
Acide perfluorononane sulfonique (PFNS) <0,002 µg/L
Acide perfluoropentanoïque (PFPEA) <0,005 µg/L
Acide perfluorobutanoïque (PFBA) <0,005 µg/L
Acide perfluoroheptane sulfonique (PFHpS) <0,002 µg/L
Acide perfluorohexanoïque (PFHXA) <0,005 µg/L
Acide perfluoro undecanoïque (PFUnA) <0,002 µg/L

Above our health benchmark. Here are some filter options.

EU legal limit
27 ng/L sum of 20 PFAS, below the 100 ng/L limit
Last PFAS test
30 July 2026
Water supplier
SAUR FRANCE

In Vignot, the 4 most closely watched PFAS (PFAS-4) add up to 22 ng/L (0.022 µg/L) at the latest PFAS check on 30 July 2026. That's 44 times our 0.5 ng/L health benchmark, and above Sweden's legal limit of 4 ng/L. Sum of 20 PFAS: 27 ng/L (0.027 µg/L), below the EU legal limit (100 ng/L). 2 checks since 13 March 2025: sum of 20 PFAS from 11 ng/L to 27 ng/L. Source: Hub'eau, Qualité de l'eau potable (Ministère de la Santé / OFB / BRGM).

Details and sources
Water supplier: SAUR FRANCE Latest water check: 30 July 2026 Data updated on

PFAS over time in Vignot

2 PFAS checks since 13 March 2025, from the published measurements.

“Calculated”: PFAS-4 worked out from the four substances in the same sample. The chart, averages and trends use lab-published sums only.

27 ng/L013 March 202530 July 2026
Laboratory-published sum of 20 PFAS per check in ng/L. Hollow dots: below the detection limit. Calculated PFAS-4 values are listed in the table.
DatePFAS-4Sum of 20 PFAS
22 ng/L – < 24 ng/L · calculated27 ng/L
8 ng/L – < 12 ng/L · calculated11 ng/L

Calculated values: “<” is an upper bound from published thresholds, “≥” a lower bound, “–” means no published sum or complete measurement. How to read a PFAS result

What the latest check found

At the latest check, the water was within every limit tested.

Microbiology: within the limit Chemistry: within the limit

Values to watch

These results are close to their legal limit, or over it.

What was tested Value Limit Status
Nitrate 30 mg/L ≤ 50 mg/L within the limit
See all 18 test results
What was tested Value Limit Status
Nitrate 30 mg/L ≤ 50 mg/L within the limit
Nitrite <0,01 mg/L ≤ 0.5 mg/L within the limit
Arsenic 1.69 µg/L ≤ 10 µg/L within the limit
Cadmium <0,01 µg/L ≤ 5 µg/L within the limit
Chromium 0.3 µg/L ≤ 50 µg/L within the limit
Uranium 0.27 µg/L ≤ 30 µg/L within the limit
Fluoride 0.06 mg/L ≤ 1.5 mg/L within the limit
Escherichia coli <1 n/(100mL) ≤ 0 mL) within the limit
Enterococci <1 n/(100mL) ≤ 0 mL) within the limit
Coliform bacteria <1 n/(100mL) ≤ 0 mL) within the limit
pH 7.07 unité pH 6.5–9.5 pH within the limit
Water hardness 29.2 °f no limit for reference
Electrical conductivity 610 µS/cm 200–1,100 µS/cm within the limit
Chloride 15 mg/L ≤ 250 mg/L within the limit
Sulphate 23 mg/L ≤ 250 mg/L within the limit
Sodium 9.3 mg/L ≤ 200 mg/L within the limit
Iron 2 µg/L ≤ 200 µg/L within the limit
Turbidity <0,1 NFU ≤ 2 NFU within the limit

Frequently asked questions

Is tap water in Vignot safe to drink?

Yes. At the check on 30 July 2026, the tap water in Vignot was within every limit tested. “Eau d'alimentation conforme aux exigences de qualité en vigueur pour l'ensemble des paramètres mesurés. Il est à noter la présence d'Anthraquinone à une teneur de 0,69 µg/L. La présence de cette substance peut avoir pour origine une réaction entre le chlore et des matériaux à base de goudron constitutifs du revêtement intérieur de réservoir et/ou de certaines canalisations en fonte. Par conséquent, une analyse complémentaire sera réalisée afin de rechercher la présence d'hydrocarbures aromatiques polycycliques (HAP), et, le cas échéant, d'en évaluer la toxicité. Le responsable de la distribution de l'eau a été informé de cette situation et invité à prendre des mesures correctives par messagerie le 12/08.”

How high are PFAS levels in Vignot's drinking water?

The total of 20 PFAS ("forever chemicals") was last measured at 27 ng/L. The EU limit is 100 ng/L, so this water is at 27 % of the limit. (below the EU limit)

Does the water in Vignot also meet the strictest limits in Europe?

No. The four most harmful PFAS add up to 22 ng/L. That is 5.5 times Sweden's legal limit of 4 ng/L, in force since 2026. Germany will set a similar one in 2028. The water still passes the current EU legal limit (100 ng/L for the total of 20 PFAS).

Are PFAS levels rising in Vignot's tap water?

Calculated PFAS-4 values are listed in the table. The chart uses laboratory-published sum-of-20 results; there are too few laboratory-published PFAS-4 sums for the existing trend calculation.

How hard is the water in Vignot?

The water hardness in Vignot is 29.2 °f (medium). This mainly matters for household appliances and detergent dosing, not for health.

Where does this data come from?

All values come from official publications: Hub'eau, Qualité de l'eau potable (Ministère de la Santé / OFB / BRGM). Retrieved on 21 September 2026.

Nearby communes

The closest to Vignot on this site.

Data source

Hub'eau, Qualité de l'eau potable (Ministère de la Santé / OFB / BRGM)