PFAS in Salouël's tap water: under 4 ng/L, none of the four main PFAS detected

Last PFAS check: · Source: Hub'eau

PFAS in drinking water

No PFAS detected

Amount found in the water < 4 ng/L the 4 most harmful PFAS (PFAS-4) · the lab's detection limit 20 PFAS looked for, none found
Our health benchmark 0.5 ng/L

The lab sees nothing below 4 ng/L, 8 times our benchmark of 0.5 ng/L. Water above our benchmark would pass this check unnoticed.

0.5 ng/L is our benchmark, not an official limit. Same EFSA method as Sweden, Denmark and the Netherlands, but stricter. It's a yearly average, compared here with the latest check.

Sample taken in Saleux, on the same distribution network as Salouël (SALEUX SALOUEL UDI). The health authority samples one tap per network; a network carries the same treated water everywhere.

More about this result

The US also limits PFOA and PFOS to 4 ng/L each, per substance.

The lab detects each of the four substances from 1 ng/L upward. None reached that limit, so their total is below 4 ng/L rather than zero.

20 PFAS (see each substance)
PFAS substance Value
Acide perfluoropentanoïque (PFPEA) <0,001 µg/L
Acide perfluorododécanoique (PFDoDA) <0,001 µg/L
Acide perfluoro-octanoïque (PFOA) <0,001 µg/L
Acide perfluorononane sulfonique (PFNS) <0,002 µg/L
Acide perfluoro-decanoïque (PFDA) <0,001 µg/L
Acide perfluoropentane sulfonique (PFPS) <0,001 µg/L
Acide perfluorobutanoïque (PFBA) <0,002 µg/L
Acide perfluoroheptane sulfonique (PFHpS) <0,002 µg/L
Acide perfluoro tridecanoique (PFTrDA) <0,001 µg/L
Acide perfluoro-nonanoïque (PFNA) <0,001 µg/L
Acide perfluoro undecanoïque (PFUnA) <0,001 µg/L
Acide perfluorodecane sulfonique (PFDS) <0,001 µg/L
Acide perfluoro undecane sulfonique (PFUnDS) <0,002 µg/L
Acide perfluorododécane sulfonique (PFDoDS) <0,001 µg/L
Acide perfluoroheptanoïque (PFHPA) <0,001 µg/L
Acide sulfonique de perfluorobutane (PFBS) <0,001 µg/L
Acide perfluorohexanoïque (PFHXA) <0,002 µg/L
Perfluorohexane sulfonate (PFHXS) <0,001 µg/L
Acide sulfonique de perfluorooctane (PFOS) <0,001 µg/L
Acide perfluoro tridecane sulfonique (PFTrDS) <0,005 µg/L

None found. The lab sees nothing below 4 ng/L, so our 0.5 ng/L benchmark cannot be checked.

EU legal limit
none detected sum of 20 PFAS below the detection limit, limit 100 ng/L
Last PFAS test
16 July 2026
Water supplier
AMIENS METROPOLE

In Salouël, none of the 4 most closely watched PFAS (PFAS-4) was detected at the latest PFAS check on 16 July 2026. The total is below 4 ng/L, the sum of the detection limits and 8 times our 0.5 ng/L benchmark. Sum of 20 PFAS: <0,029 µg/L, below the EU legal limit (100 ng/L). Sampled in Saleux, on the same network. 3 checks since 22 January 2026, PFAS-4 always below the detection limit (4 ng/L). Source: Hub'eau, Qualité de l'eau potable (Ministère de la Santé / OFB / BRGM).

Details and sources
Water supplier: AMIENS METROPOLE Latest water check: 16 July 2026 Data updated on

PFAS over time in Salouël

4 PFAS checks since 30 January 2025, from the published measurements. Samples from 2 communes on the same network: it's the same water, so each one applies to Salouël.

“Calculated”: PFAS-4 worked out from the four substances in the same sample. The chart, averages and trends use lab-published sums only.

DatePFAS-4Sum of 20 PFASSampled at
< 4 ng/L< 29 ng/LSaleux
< 4 ng/L< 29 ng/LSalouël
< 4 ng/L< 29 ng/LSaleux
< 4 ng/L · calculated< 1 ng/LSaleux

Calculated values: “<” is an upper bound from published thresholds, “≥” a lower bound, “–” means no published sum or complete measurement. How to read a PFAS result

What the latest check found

At the latest check, the water was within every limit tested.

Microbiology: within the limit Chemistry: within the limit

Values to watch

These results are close to their legal limit, or over it.

What was tested Value Limit Status
Nitrate 28.9 mg/L ≤ 50 mg/L within the limit
See all 21 test results
What was tested Value Limit Status
Nitrate 28.9 mg/L ≤ 50 mg/L within the limit
Nitrite <0,010 mg/L ≤ 0.5 mg/L within the limit
Lead 0.7 µg/L ≤ 10 µg/L within the limit
Copper 0.05 mg(Cu)/L ≤ 2 mg(Cu)/L within the limit
Nickel <0,5 µg/L ≤ 20 µg/L within the limit
Arsenic <0,5 µg/L ≤ 10 µg/L within the limit
Cadmium <0,5 µg/L ≤ 5 µg/L within the limit
Chromium <0,5 µg/L ≤ 50 µg/L within the limit
Uranium <10 µg/L ≤ 30 µg/L within the limit
Fluoride 0.153 mg/L ≤ 1.5 mg/L within the limit
Escherichia coli 0 n/(100mL) ≤ 0 mL) within the limit
Enterococci 0 n/(100mL) ≤ 0 mL) within the limit
Coliform bacteria 0 n/(100mL) ≤ 0 mL) within the limit
pH 7.3 unité pH 6.5–9 unité pH within the limit
Water hardness 27.9 °f no limit for reference
Electrical conductivity 620 µS/cm 200–1,100 µS/cm within the limit
Chloride 26.3 mg/L ≤ 250 mg/L within the limit
Sulphate 5.6 mg/L ≤ 250 mg/L within the limit
Sodium 12.8 mg/L ≤ 200 mg/L within the limit
Iron <5 µg/L ≤ 200 µg/L within the limit
Turbidity <0,30 NFU ≤ 2 NFU within the limit

Frequently asked questions

Is tap water in Salouël safe to drink?

Yes. At the check on 16 July 2026, the tap water in Salouël was within every limit tested. “Eau d'alimentation conforme aux exigences de qualité en vigueur pour l'ensemble des paramètres mesurés. J'attire votre attention sur la concentration élevée en bactéries aérobies revivifiables qui nécessite un suivi renforcé de vos installations, notamment une surveillance et un réglage des installations de désinfection. En attendant, l'eau reste consommable.”

How high are PFAS levels in Salouël's drinking water?

At the latest check the total of 20 PFAS ("forever chemicals") was below the laboratory's reporting limit of 29 ng/L. The EU limit is 100 ng/L, so this water is under 29 % of the limit. (below the EU limit)

Does the water in Salouël also meet the strictest limits in Europe?

As far as this check can tell, yes. None of the four compounds was quantified, so their total is below 4 ng/L, the sum of the laboratory's detection limits, and under Sweden's legal limit of 4 ng/L in force since 2026.

Are PFAS levels rising in Salouël's tap water?

No. Since 30 January 2025, 3 checks have been published and the PFAS-4 sum stayed below the laboratory's detection limit (4 ng/L) every time. These history statistics use laboratory-published sums only.

How hard is the water in Salouël?

The water hardness in Salouël is 27.9 °f (medium). This mainly matters for household appliances and detergent dosing, not for health.

Where does this data come from?

All values come from official publications: Hub'eau, Qualité de l'eau potable (Ministère de la Santé / OFB / BRGM). Retrieved on 28 September 2026.

Same water network

Same distribution network as Salouël, so in principle the same water.

Nearby communes

The closest to Salouël on this site.

Data source

Hub'eau, Qualité de l'eau potable (Ministère de la Santé / OFB / BRGM)
https://hubeau.eaufrance.fr/api/v1/qualite_eau_potable/resultats_dis?code_commune=80725
License
Licence Ouverte / Open Licence (Etalab)
Retrieved
28 September 2026
Supply networks
SALEUX SALOUEL UDI