PFAS in the tap water of Sainte-Marie (Ille-et-Vilaine): 3.06 ng/L, 6.1x our 0.5 ng/L benchmark

Last PFAS check: · Source: Hub'eau

PFAS in drinking water

6.1× above our health benchmark

Amount found in the water 3.06 ng/L 0.0031 µg/L · the 4 most harmful PFAS (PFAS-4)
Our health benchmark 0.5 ng/L

0.5 ng/L is our benchmark, not an official limit. Same EFSA method as Sweden, Denmark and the Netherlands, but stricter. It's a yearly average, compared here with the latest check.

Sample taken in Bains-sur-Oust, on the same distribution network as Sainte-Marie (REDON_CHAMP JAMET_BAIN SUR OUST). The health authority samples one tap per network; a network carries the same treated water everywhere.

More about this result

The US also limits PFOA and PFOS to 4 ng/L each, per substance.

Substances below the detection limit count as 0, so the real total may be higher.

One of these four, PFOA, is classified as causing cancer in humans by the WHO's cancer research agency (IARC).

More PFAS than in 89% of the cities we track

20 PFAS (see each substance)
PFAS substance Value
Acide perfluorohexanoïque (PFHXA) 0.0021 µg/L
Acide perfluoro-octanoïque (PFOA) 0.0015 µg/L
Acide perfluoroheptanoïque (PFHPA) 0.0012 µg/L
Acide sulfonique de perfluorobutane (PFBS) 0.0011 µg/L
Acide sulfonique de perfluorooctane (PFOS) 0.001 µg/L
Perfluorohexane sulfonate (PFHXS) 0.0006 µg/L
Acide perfluorododécanoique (PFDoDA) <0,0010 µg/L
Acide perfluoroheptane sulfonique (PFHpS) <0,00040 µg/L
Acide perfluoropentanoïque (PFPEA) <0,0050 µg/L
Acide perfluoro tridecanoique (PFTrDA) <0,0010 µg/L
Acide perfluorononane sulfonique (PFNS) <0,00040 µg/L
Acide perfluorododécane sulfonique (PFDoDS) <0,00040 µg/L
Acide perfluoro-nonanoïque (PFNA) <0,0010 µg/L
Acide perfluoro-decanoïque (PFDA) <0,0010 µg/L
Acide perfluorobutanoïque (PFBA) <0,0050 µg/L
Acide perfluoropentane sulfonique (PFPS) <0,00040 µg/L
Acide perfluoro undecanoïque (PFUnA) <0,0010 µg/L
Acide perfluoro tridecane sulfonique (PFTrDS) <0,00040 µg/L
Acide perfluoro undecane sulfonique (PFUnDS) <0,00040 µg/L
Acide perfluorodecane sulfonique (PFDS) <0,00040 µg/L

Above our health benchmark. Here are some filter options.

EU legal limit
7.41 ng/L sum of 20 PFAS, below the 100 ng/L limit
Last PFAS test
19 May 2026
Water supplier
SAUR 35

In Sainte-Marie, the 4 most closely watched PFAS (PFAS-4) add up to 3.06 ng/L (0.0031 µg/L) at the latest PFAS check on 19 May 2026. That's 6.1 times our 0.5 ng/L health benchmark, but below Sweden's legal limit of 4 ng/L. Sum of 20 PFAS: 7.41 ng/L (0.0074 µg/L), below the EU legal limit (100 ng/L). Sampled in Bains-sur-Oust, on the same network. 3 checks since 21 July 2025: PFAS-4 from 1.9 ng/L to 3.06 ng/L, averaging 2.33 ng/L over 12 months. Rising on the main network. Source: Hub'eau, Qualité de l'eau potable (Ministère de la Santé / OFB / BRGM).

Details and sources
Water supplier: SAUR 35 Latest water check: 2 July 2026 Data updated on

PFAS over time in Sainte-Marie

3 PFAS checks since 21 July 2025, values as published.

0.5 ng/L3.06 ng/L021 July 202519 May 2026
PFAS-4 sum per check in ng/L. Dashed line: pfasnearme's 0.5 ng/L benchmark. Hollow dots: below the detection limit.
DatePFAS-4Sum of 20 PFASSampled at
3.06 ng/L7.41 ng/LBains-sur-Oust
2.04 ng/L6.07 ng/LBains-sur-Oust
1.9 ng/L6.56 ng/LBains-sur-Oust

“<” means not detected, the figure being the detection limit. “–” means not published. Labs have only reported the PFAS-4 sum (SANDRE code 9268) since autumn 2025. How to read a PFAS result

What the latest check found

At the latest check, the water was within every limit tested.

Microbiology: within the limit Chemistry: within the limit
See all 17 test results
What was tested Value Limit Status
Nitrate 12.7 mg/L ≤ 50 mg/L within the limit
Nitrite <0,02 mg/L ≤ 0.5 mg/L within the limit
Lead <1,0 µg/L ≤ 10 µg/L within the limit
Copper 0.0197 mg(Cu)/L ≤ 2 mg(Cu)/L within the limit
Nickel 2.7 µg/L ≤ 20 µg/L within the limit
Cadmium <0,025 µg/L ≤ 5 µg/L within the limit
Chromium <1,0 µg/L ≤ 50 µg/L within the limit
Escherichia coli 0 n/(100mL) ≤ 0 mL) within the limit
Enterococci 0 n/(100mL) ≤ 0 mL) within the limit
Coliform bacteria 0 n/(100mL) ≤ 0 mL) within the limit
pH 8.2 unité pH 6.5–9 unité pH within the limit
Water hardness 14.3 °f no limit for reference
Electrical conductivity 472 µS/cm 200–1,100 µS/cm within the limit
Chloride 79.2 mg/L ≤ 250 mg/L within the limit
Sulphate 23.2 mg/L ≤ 250 mg/L within the limit
Iron <20 µg/L ≤ 200 µg/L within the limit
Turbidity <0,20 NFU ≤ 2 NFU within the limit

Frequently asked questions

Is tap water in Sainte-Marie safe to drink?

Yes. At the check on 2 July 2026, the tap water in Sainte-Marie was within every limit tested. “Eau d'alimentation conforme aux limites réglementaires en vigueur, mais ne respectant pas la référence de qualité fixée pour le paramètre température en ce point d'échantillonage. A noter également en ce point d'échantillonnage, la présence d'une flore revivifiable anormalement élevée en l'absence de chlore libre résiduel (objectif souhaitable : 0,1 mg/l en tout point du réseau). L'exploitant a été informé de cette situation dès connaissance de celle-ci par mon service, pour vérifications et actions correctives d'usage.”

How high are PFAS levels in Sainte-Marie's drinking water?

The total of 20 PFAS ("forever chemicals") was last measured at 7.41 ng/L. The EU limit is 100 ng/L, so this water is at 7 % of the limit. (below the EU limit)

Does the water in Sainte-Marie also meet the strictest limits in Europe?

Yes. Even against Europe's strictest legal limit, Sweden's 4 ng/L in force since 2026, the measured value of 3.06 ng/L stays below.

Are PFAS levels rising in Sainte-Marie's tap water?

Yes. On the main network, the PFAS-4 sum rose from 1.9 ng/L (21 July 2025) to 3.06 ng/L (19 May 2026) across 3 quantified checks. pfasnearme's benchmark is 0.5 ng/L as an annual mean.

How hard is the water in Sainte-Marie?

The water hardness in Sainte-Marie is 14.3 °f (soft). This mainly matters for household appliances and detergent dosing, not for health.

Where does this data come from?

All values come from official publications: Hub'eau, Qualité de l'eau potable (Ministère de la Santé / OFB / BRGM). Retrieved on 21 September 2026.

Same water network

Same distribution network as Sainte-Marie, so in principle the same water.

Nearby communes

The closest to Sainte-Marie on this site.

Data source

Hub'eau, Qualité de l'eau potable (Ministère de la Santé / OFB / BRGM)
https://hubeau.eaufrance.fr/api/v1/qualite_eau_potable/resultats_dis?code_commune=35294
License
Licence Ouverte / Open Licence (Etalab)
Retrieved
21 September 2026
Supply networks
REDON_CHAMP JAMET_BAIN SUR OUST

This site is a data project, not an official source. If in doubt, check with your water supplier or local authority.