PFAS in Sainte-Colombe-près-Vernon's tap water: 2.2 ng/L, 4.4x our 0.5 ng/L benchmark

Last PFAS check: · Source: Hub'eau

PFAS in drinking water

4.4× above our health benchmark

Amount found in the water 2.2 ng/L 0.0022 µg/L · the 4 most harmful PFAS (PFAS-4)
Our health benchmark 0.5 ng/L

0.5 ng/L is our benchmark, not an official limit. Same EFSA method as Sweden, Denmark and the Netherlands, but stricter. It's a yearly average, compared here with the latest check.

Sample taken in Chambray, on the same distribution network as Sainte-Colombe-près-Vernon (HOULBEC COCHEREL). The health authority samples one tap per network; a network carries the same treated water everywhere.

More about this result

The US also limits PFOA and PFOS to 4 ng/L each, per substance.

Substances below the detection limit count as 0, so the real total may be higher.

One of these four, PFOA, is classified as causing cancer in humans by the WHO's cancer research agency (IARC).

More PFAS than in 88% of the cities we track

20 PFAS (see each substance)
PFAS substance Value
Acide perfluoropentanoïque (PFPEA) 0.0032 µg/L
Perfluorohexane sulfonate (PFHXS) 0.0022 µg/L
Acide sulfonique de perfluorooctane (PFOS) <0,0010 µg/L
Acide perfluorodecane sulfonique (PFDS) <0,0010 µg/L
Acide perfluoro tridecane sulfonique (PFTrDS) <0,0010 µg/L
Acide perfluorododécanoique (PFDoDA) <0,0020 µg/L
Acide perfluoro undecane sulfonique (PFUnDS) <0,0010 µg/L
Acide perfluoro-decanoïque (PFDA) <0,0020 µg/L
Acide perfluorododécane sulfonique (PFDoDS) <0,0010 µg/L
Acide perfluoro-nonanoïque (PFNA) <0,0010 µg/L
Acide perfluorohexanoïque (PFHXA) <0,0050 µg/L
Acide perfluoroheptanoïque (PFHPA) <0,0050 µg/L
Acide perfluoroheptane sulfonique (PFHpS) <0,0020 µg/L
Acide perfluoro tridecanoique (PFTrDA) <0,0020 µg/L
Acide perfluoropentane sulfonique (PFPS) <0,0010 µg/L
Acide sulfonique de perfluorobutane (PFBS) <0,0050 µg/L
Acide perfluorobutanoïque (PFBA) <0,0050 µg/L
Acide perfluorononane sulfonique (PFNS) <0,0010 µg/L
Acide perfluoro-octanoïque (PFOA) <0,0020 µg/L
Acide perfluoro undecanoïque (PFUnA) <0,0020 µg/L

Above our health benchmark. Here are some filter options.

EU legal limit
5.4 ng/L sum of 20 PFAS, below the 100 ng/L limit
Last PFAS test
26 February 2025
Water supplier
STGS

In Sainte-Colombe-près-Vernon, the 4 most closely watched PFAS (PFAS-4) add up to 2.2 ng/L (0.0022 µg/L) at the latest PFAS check on 26 February 2025. That's 4.4 times our 0.5 ng/L health benchmark, but below Sweden's legal limit of 4 ng/L. Sum of 20 PFAS: 5.4 ng/L (0.0054 µg/L), below the EU legal limit (100 ng/L). Sampled in Chambray, on the same network. Source: Hub'eau, Qualité de l'eau potable (Ministère de la Santé / OFB / BRGM).

Details and sources
Water supplier: STGS Latest water check: 1 April 2026 Data updated on

PFAS over time in Sainte-Colombe-près-Vernon

A single PFAS check has been published for Sainte-Colombe-près-Vernon so far (26 February 2025). A history will build up with the next checks; this page is refreshed weekly.

What the latest check found

At the latest check, the water was within every limit tested.

Microbiology: within the limit Chemistry: within the limit

Values to watch

These results are close to their legal limit, or over it.

Outside a reference value: Turbidity 2.15 NFU on 1 April 2026 (reference ≤ 2 NFU). These are indicator parameters with reference values, not legal limits.

What was tested Value Limit Status
Nitrate 28.3 mg/L ≤ 50 mg/L within the limit
Turbidity 2.15 NFU ≤ 2 NFU above the reference value
See all 13 test results
What was tested Value Limit Status
Nitrate 28.3 mg/L ≤ 50 mg/L within the limit
Nitrite <0,010 mg/L ≤ 0.5 mg/L within the limit
Cadmium <0,10 µg/L ≤ 5 µg/L within the limit
Chromium <0,50 µg/L ≤ 50 µg/L within the limit
Escherichia coli <1 n/(100mL) ≤ 0 mL) within the limit
Enterococci <1 n/(100mL) ≤ 0 mL) within the limit
Coliform bacteria <1 n/(100mL) ≤ 0 mL) within the limit
pH 7.7 unité pH 6.5–9 unité pH within the limit
Water hardness 31 °f no limit for reference
Electrical conductivity 619 µS/cm 200–1,100 µS/cm within the limit
Chloride 25.5 mg/L ≤ 250 mg/L within the limit
Sulphate 17 mg/L ≤ 250 mg/L within the limit
Turbidity 2.15 NFU ≤ 2 NFU above the reference value

Frequently asked questions

Is tap water in Sainte-Colombe-près-Vernon safe to drink?

Yes. At the check on 1 April 2026, the tap water in Sainte-Colombe-près-Vernon was within every limit tested. Outside a reference value: Turbidity 2.15 NFU on 1 April 2026 (reference ≤ 2 NFU). These are indicator parameters with reference values, not legal limits. “Eau d'alimentation conforme aux limites de qualité en vigueur pour les paramètres mesurés. Toutefois, la référence de qualité fixée pour pour la turbidité n'est pas satisfaite, sans empêcher la consommation de l'eau. La concentration en chlore est insuffisante.”

How high are PFAS levels in Sainte-Colombe-près-Vernon's drinking water?

The total of 20 PFAS ("forever chemicals") was last measured at 5.4 ng/L. The EU limit is 100 ng/L, so this water is at 5 % of the limit. (below the EU limit)

Does the water in Sainte-Colombe-près-Vernon also meet the strictest limits in Europe?

Yes. Even against Europe's strictest legal limit, Sweden's 4 ng/L in force since 2026, the measured value of 2.2 ng/L stays below.

How hard is the water in Sainte-Colombe-près-Vernon?

The water hardness in Sainte-Colombe-près-Vernon is 31 °f (hard). This mainly matters for household appliances and detergent dosing, not for health.

Where does this data come from?

All values come from official publications: Hub'eau, Qualité de l'eau potable (Ministère de la Santé / OFB / BRGM). Retrieved on 12 September 2026.

Same water network

Same distribution network as Sainte-Colombe-près-Vernon, so in principle the same water.

Nearby communes

The closest to Sainte-Colombe-près-Vernon on this site.

Data source

Hub'eau, Qualité de l'eau potable (Ministère de la Santé / OFB / BRGM)
https://hubeau.eaufrance.fr/api/v1/qualite_eau_potable/resultats_dis?code_commune=27525
License
Licence Ouverte / Open Licence (Etalab)
Retrieved
12 September 2026
Supply networks
HOULBEC COCHEREL

This site is a data project, not an official source. If in doubt, check with your water supplier or local authority.