PFAS in Millay's tap water: under 4 ng/L, none of the four main PFAS detected
Last PFAS check: · Source: Hub'eau
PFAS in drinking water
No PFAS detected
The lab sees nothing below 4 ng/L, 8 times our benchmark of 0.5 ng/L. Water above our benchmark would pass this check unnoticed.
0.5 ng/L is our benchmark, not an official limit. Same EFSA method as Sweden, Denmark and the Netherlands, but stricter. It's a yearly average, compared here with the latest check.
Sample taken in Larochemillay, on the same distribution network as Millay (RESEAU DE LUZY). The health authority samples one tap per network; a network carries the same treated water everywhere.
More about this result
The US also limits PFOA and PFOS to 4 ng/L each, per substance.
The lab detects each of the four substances from 1 ng/L upward. None reached that limit, so their total is below 4 ng/L rather than zero.
checked on 26 January 2026
20 PFAS (see each substance)
| PFAS substance | Value |
|---|---|
| Acide perfluoro undecanoïque (PFUnA) | <0,001 µg/L |
| Acide perfluoro undecane sulfonique (PFUnDS) | <0,002 µg/L |
| Acide perfluoro tridecane sulfonique (PFTrDS) | <0,005 µg/L |
| Acide perfluoroheptanoïque (PFHPA) | <0,001 µg/L |
| Acide perfluorododécanoique (PFDoDA) | <0,001 µg/L |
| Acide perfluorodecane sulfonique (PFDS) | <0,001 µg/L |
| Acide sulfonique de perfluorobutane (PFBS) | <0,001 µg/L |
| Perfluorohexane sulfonate (PFHXS) | <0,001 µg/L |
| Acide sulfonique de perfluorooctane (PFOS) | <0,001 µg/L |
| Acide perfluoro-decanoïque (PFDA) | <0,001 µg/L |
| Acide perfluoropentane sulfonique (PFPS) | <0,001 µg/L |
| Acide perfluorohexanoïque (PFHXA) | <0,002 µg/L |
| Acide perfluorododécane sulfonique (PFDoDS) | <0,001 µg/L |
| Acide perfluorononane sulfonique (PFNS) | <0,002 µg/L |
| Acide perfluoro-nonanoïque (PFNA) | <0,001 µg/L |
| Acide perfluoro tridecanoique (PFTrDA) | <0,001 µg/L |
| Acide perfluoroheptane sulfonique (PFHpS) | <0,002 µg/L |
| Acide perfluoropentanoïque (PFPEA) | <0,002 µg/L |
| Acide perfluoro-octanoïque (PFOA) | <0,001 µg/L |
| Acide perfluorobutanoïque (PFBA) | <0,002 µg/L |
None found. The lab sees nothing below 4 ng/L, so our 0.5 ng/L benchmark cannot be checked.
Water report for Millay
Get new PFAS results for Millay, with a short explanation. At most one update a week, only when there's something new.
- EU legal limit
- none detected sum of 20 PFAS below the detection limit, limit 100 ng/L
- Last PFAS test
- 26 January 2026
- Water supplier
- SAUR CENTRE RHIN RHONE
In Millay, none of the 4 most closely watched PFAS (PFAS-4) was detected at the latest PFAS check on 26 January 2026. The total is below 4 ng/L, the sum of the detection limits and 8 times our 0.5 ng/L benchmark. Sum of 20 PFAS: <0,029 µg/L, below the EU legal limit (100 ng/L). Sampled in Larochemillay, on the same network. 2 checks since 26 January 2026, PFAS-4 always below the detection limit (4 ng/L). Source: Hub'eau, Qualité de l'eau potable (Ministère de la Santé / OFB / BRGM).
Details and sources
PFAS over time in Millay
4 PFAS checks since 5 May 2025, from the published measurements. Samples from 2 communes on the same network: it's the same water, so each one applies to Millay.
“Calculated”: PFAS-4 worked out from the four substances in the same sample. The chart, averages and trends use lab-published sums only.
| Date | PFAS-4 | Sum of 20 PFAS | Sampled at |
|---|---|---|---|
| < 4 ng/L | < 29 ng/L | Millay | |
| < 4 ng/L | < 29 ng/L | Larochemillay | |
| < 4 ng/L · calculated | < 100 ng/L | Larochemillay | |
| < 4 ng/L · calculated | 1 ng/L | Millay |
Calculated values: “<” is an upper bound from published thresholds, “≥” a lower bound, “–” means no published sum or complete measurement. How to read a PFAS result
What the latest check found
At the latest check, the water was within every limit tested.
Values to watch
These results are close to their legal limit, or over it.
Outside a reference value: pH 9.7 unité pH on 20 March 2026 (reference 6.5–9 unité pH), Electrical conductivity 90 µS/cm on 20 March 2026 (reference 200–1,100 µS/cm). These are indicator parameters with reference values, not legal limits.
| What was tested | Value | Limit | Status |
|---|---|---|---|
| pH | 9.7 unité pH | 6.5–9 unité pH | above the reference value |
| Electrical conductivity | 90 µS/cm | 200–1,100 µS/cm | below the reference value |
See all 21 test results
| What was tested | Value | Limit | Status |
|---|---|---|---|
| Nitrate | 3.3 mg/L | ≤ 50 mg/L | within the limit |
| Nitrite | <0,01 mg/L | ≤ 0.5 mg/L | within the limit |
| Lead | 4 µg/L | ≤ 10 µg/L | within the limit |
| Copper | 0.038 mg(Cu)/L | ≤ 2 mg(Cu)/L | within the limit |
| Nickel | <5 µg/L | ≤ 20 µg/L | within the limit |
| Arsenic | <2 µg/L | ≤ 10 µg/L | within the limit |
| Cadmium | <1 µg/L | ≤ 5 µg/L | within the limit |
| Chromium | <5 µg/L | ≤ 50 µg/L | within the limit |
| Uranium | <10 µg/L | ≤ 30 µg/L | within the limit |
| Fluoride | 0.07 mg/L | ≤ 1.5 mg/L | within the limit |
| Escherichia coli | <1 n/(100mL) | ≤ 0 mL) | within the limit |
| Enterococci | <1 n/(100mL) | ≤ 0 mL) | within the limit |
| Coliform bacteria | <1 n/(100mL) | ≤ 0 mL) | within the limit |
| pH | 9.7 unité pH | 6.5–9 unité pH | above the reference value |
| Water hardness | 3.28 °f | no limit | for reference |
| Electrical conductivity | 90 µS/cm | 200–1,100 µS/cm | below the reference value |
| Chloride | 5.7 mg/L | ≤ 250 mg/L | within the limit |
| Sulphate | 5.1 mg/L | ≤ 250 mg/L | within the limit |
| Sodium | 5 mg/L | ≤ 200 mg/L | within the limit |
| Iron | <10 µg/L | ≤ 200 µg/L | within the limit |
| Turbidity | 0.58 NFU | ≤ 2 NFU | within the limit |
Frequently asked questions
Is tap water in Millay safe to drink?
Yes. At the check on 20 March 2026, the tap water in Millay was within every limit tested. Outside a reference value: pH 9.7 unité pH on 20 March 2026 (reference 6.5–9 unité pH), Electrical conductivity 90 µS/cm on 20 March 2026 (reference 200–1,100 µS/cm). These are indicator parameters with reference values, not legal limits. “La teneur en chlore est insuffisante pour garantir une désinfection ef ficace de l’eau distribuée sur l’ensemble du réseau. Il est recommandé de maintenir au moins 0,1 mg/L en tout point du réseau. Le PH est inf érieur à la référence réglementaire de 6.5 unité pH. Il favorise la di ssolution des métaux des canalisations et des robinets. Les autres par amètres mesurés répondent aux normes de potabilité, excepté la conduct ivité.”
How high are PFAS levels in Millay's drinking water?
At the latest check the total of 20 PFAS ("forever chemicals") was below the laboratory's reporting limit of 29 ng/L. The EU limit is 100 ng/L, so this water is under 29 % of the limit. (below the EU limit)
Does the water in Millay also meet the strictest limits in Europe?
As far as this check can tell, yes. None of the four compounds was quantified, so their total is below 4 ng/L, the sum of the laboratory's detection limits, and under Sweden's legal limit of 4 ng/L in force since 2026.
Are PFAS levels rising in Millay's tap water?
Too few quantified checks to say (0 since 5 May 2025). pfasnearme adds each new publication weekly; a trend needs at least three quantified values. These history statistics use laboratory-published sums only.
How hard is the water in Millay?
The water hardness in Millay is 3.3 °f (soft). This mainly matters for household appliances and detergent dosing, not for health.
Where does this data come from?
All values come from official publications: Hub'eau, Qualité de l'eau potable (Ministère de la Santé / OFB / BRGM). Retrieved on 12 September 2026.
Same water network
Same distribution network as Millay, so in principle the same water.
Nearby communes
The closest to Millay on this site.
Data source
- Hub'eau, Qualité de l'eau potable (Ministère de la Santé / OFB / BRGM)
- https://hubeau.eaufrance.fr/api/v1/qualite_eau_potable/resultats_dis?code_commune=58168
- License
- Licence Ouverte / Open Licence (Etalab)
- Retrieved
- 12 September 2026
- Supply networks
- RESEAU DE LUZY
This site is a data project, not an official source. If in doubt, check with your water supplier or local authority.