PFAS in the tap water of Mélisey (Haute-Saône): under 4 ng/L, none of the four main PFAS detected
Last PFAS check: · Source: Hub'eau
PFAS in drinking water
No PFAS detected
The lab sees nothing below 4 ng/L, 8 times our benchmark of 0.5 ng/L. Water above our benchmark would pass this check unnoticed.
0.5 ng/L is our benchmark, not an official limit. Same EFSA method as Sweden, Denmark and the Netherlands, but stricter. It's a yearly average, compared here with the latest check.
More about this result
The US also limits PFOA and PFOS to 4 ng/L each, per substance.
The lab detects each of the four substances from 1 ng/L upward. None reached that limit, so their total is below 4 ng/L rather than zero.
checked on 3 November 2025
20 PFAS (see each substance)
| PFAS substance | Value |
|---|---|
| Acide perfluoroheptane sulfonique (PFHpS) | <0,002 µg/L |
| Acide perfluoro undecane sulfonique (PFUnDS) | <0,002 µg/L |
| Acide perfluoro tridecanoique (PFTrDA) | <0,001 µg/L |
| Acide perfluoropentane sulfonique (PFPS) | <0,001 µg/L |
| Acide sulfonique de perfluorobutane (PFBS) | <0,001 µg/L |
| Acide perfluorododécane sulfonique (PFDoDS) | <0,001 µg/L |
| Acide perfluorodecane sulfonique (PFDS) | <0,001 µg/L |
| Acide perfluorononane sulfonique (PFNS) | <0,002 µg/L |
| Acide perfluoroheptanoïque (PFHPA) | <0,001 µg/L |
| Acide perfluorohexanoïque (PFHXA) | <0,002 µg/L |
| Acide perfluoro-decanoïque (PFDA) | <0,001 µg/L |
| Acide perfluoro-octanoïque (PFOA) | <0,001 µg/L |
| Acide perfluorododécanoique (PFDoDA) | <0,001 µg/L |
| Acide perfluoro undecanoïque (PFUnA) | <0,001 µg/L |
| Perfluorohexane sulfonate (PFHXS) | <0,001 µg/L |
| Acide perfluoro-nonanoïque (PFNA) | <0,001 µg/L |
| Acide perfluorobutanoïque (PFBA) | <0,002 µg/L |
| Acide perfluoro tridecane sulfonique (PFTrDS) | <0,005 µg/L |
| Acide sulfonique de perfluorooctane (PFOS) | <0,001 µg/L |
| Acide perfluoropentanoïque (PFPEA) | <0,001 µg/L |
None found. The lab sees nothing below 4 ng/L, so our 0.5 ng/L benchmark cannot be checked.
Water report for Mélisey
Get new PFAS results for Mélisey, with a short explanation. At most one update a week, only when there's something new.
- EU legal limit
- none detected sum of 20 PFAS below the detection limit, limit 100 ng/L
- Last PFAS test
- 3 November 2025
- Water supplier
- MAIRIE DE MELISEY
In Mélisey, none of the 4 most closely watched PFAS (PFAS-4) was detected at the latest PFAS check on 3 November 2025. The total is below 4 ng/L, the sum of the detection limits and 8 times our 0.5 ng/L benchmark. Sum of 20 PFAS: <0,029 µg/L, below the EU legal limit (100 ng/L). 2 checks since 23 September 2025, PFAS-4 always below the detection limit (4 ng/L). Source: Hub'eau, Qualité de l'eau potable (Ministère de la Santé / OFB / BRGM).
Details and sources
PFAS over time in Mélisey
7 PFAS checks since 18 March 2025, from the published measurements. Samples from 3 communes on the same network: it's the same water, so each one applies to Mélisey. Samples come from 6 distribution networks. The trend refers to the network “MELISEY HAMEAUX NORD”.
“Calculated”: PFAS-4 worked out from the four substances in the same sample. The chart, averages and trends use lab-published sums only.
| Date | PFAS-4 | Sum of 20 PFAS | Sampled at | Network |
|---|---|---|---|---|
| < 4 ng/L | < 29 ng/L | Mélisey | MELISEY LES GOUTTES | |
| < 4 ng/L | < 29 ng/L | Ternuay-Melay-et-Saint-Hilaire | MELISEY HAMEAUX NORD | |
| < 4 ng/L · calculated | < 100 ng/L | Mélisey | MELISEY SOUHIERES | |
| < 4 ng/L · calculated | < 100 ng/L | Saint-Barthélemy | MELISEY PUITS DES GRAVIERS | |
| < 4 ng/L · calculated | < 100 ng/L | Ternuay-Melay-et-Saint-Hilaire | MELISEY HAMEAUX NORD | |
| < 4 ng/L · calculated | < 100 ng/L | Mélisey | MELISEY ROCHERET | |
| < 4 ng/L · calculated | < 100 ng/L | Mélisey | MELISEY GOULOTTE |
Calculated values: “<” is an upper bound from published thresholds, “≥” a lower bound, “–” means no published sum or complete measurement. How to read a PFAS result
What the latest check found
At the latest check, the water was within every limit tested.
Values to watch
These results are close to their legal limit, or over it.
Outside a reference value: Electrical conductivity 71 µS/cm on 28 July 2026 (reference 200–1,100 µS/cm). These are indicator parameters with reference values, not legal limits.
| What was tested | Value | Limit | Status |
|---|---|---|---|
| Electrical conductivity | 71 µS/cm | 200–1,100 µS/cm | below the reference value |
See all 20 test results
| What was tested | Value | Limit | Status |
|---|---|---|---|
| Nitrate | 4.4 mg/L | ≤ 50 mg/L | within the limit |
| Nitrite | <0,020 mg/L | ≤ 0.5 mg/L | within the limit |
| Lead | <2 µg/L | ≤ 10 µg/L | within the limit |
| Copper | 0.184 mg(Cu)/L | ≤ 2 mg(Cu)/L | within the limit |
| Nickel | <5 µg/L | ≤ 20 µg/L | within the limit |
| Arsenic | <2 µg/L | ≤ 10 µg/L | within the limit |
| Cadmium | <1 µg/L | ≤ 5 µg/L | within the limit |
| Chromium | <5 µg/L | ≤ 50 µg/L | within the limit |
| Fluoride | <0,05 mg/L | ≤ 1.5 mg/L | within the limit |
| Escherichia coli | <1 n/(100mL) | ≤ 0 mL) | within the limit |
| Enterococci | <1 n/(100mL) | ≤ 0 mL) | within the limit |
| Coliform bacteria | <1 n/(100mL) | ≤ 0 mL) | within the limit |
| pH | 6.8 unité pH | 6.5–9 unité pH | within the limit |
| Water hardness | 1.4 °f | no limit | for reference |
| Electrical conductivity | 71 µS/cm | 200–1,100 µS/cm | below the reference value |
| Chloride | 4.3 mg/L | ≤ 250 mg/L | within the limit |
| Sulphate | 3 mg/L | ≤ 250 mg/L | within the limit |
| Sodium | 3.8 mg/L | ≤ 200 mg/L | within the limit |
| Iron | 71.5 µg/L | ≤ 200 µg/L | within the limit |
| Turbidity | <0,50 NFU | ≤ 2 NFU | within the limit |
Frequently asked questions
Is tap water in Mélisey safe to drink?
Yes. At the check on 28 July 2026, the tap water in Mélisey was within every limit tested. Outside a reference value: Electrical conductivity 71 µS/cm on 28 July 2026 (reference 200–1,100 µS/cm). These are indicator parameters with reference values, not legal limits. “Le taux de désinfectant trop élevé donne à l'eau un goût et des odeurs et peut conduire à la formation de sous produits indésirables (la valeur recommandée en désinfectant est à 0,1 mg/l). La conductivité inférieure à la référence peut favoriser la dissolutio n des métaux dans les canalisations en plomb et cuivre. Néanmoins, l'eau peut être consommée.”
How high are PFAS levels in Mélisey's drinking water?
At the latest check the total of 20 PFAS ("forever chemicals") was below the laboratory's reporting limit of 29 ng/L. The EU limit is 100 ng/L, so this water is under 29 % of the limit. (below the EU limit)
Does the water in Mélisey also meet the strictest limits in Europe?
As far as this check can tell, yes. None of the four compounds was quantified, so their total is below 4 ng/L, the sum of the laboratory's detection limits, and under Sweden's legal limit of 4 ng/L in force since 2026.
Are PFAS levels rising in Mélisey's tap water?
Too few quantified checks to say (0 since 18 March 2025). pfasnearme adds each new publication weekly; a trend needs at least three quantified values. These history statistics use laboratory-published sums only.
How hard is the water in Mélisey?
The water hardness in Mélisey is 1.4 °f (soft). This mainly matters for household appliances and detergent dosing, not for health.
Where does this data come from?
All values come from official publications: Hub'eau, Qualité de l'eau potable (Ministère de la Santé / OFB / BRGM). Retrieved on 21 September 2026.
Nearby communes
The closest to Mélisey on this site.
Data source
- Hub'eau, Qualité de l'eau potable (Ministère de la Santé / OFB / BRGM)
- https://hubeau.eaufrance.fr/api/v1/qualite_eau_potable/resultats_dis?code_commune=70339
- License
- Licence Ouverte / Open Licence (Etalab)
- Retrieved
- 21 September 2026
- Supply networks
- MELISEY SOUHIERES, MELISEY GOULOTTE, MELISEY ROCHERET, MELISEY HAMEAUX NORD, MELISEY PUITS DES GRAVIERS, MELISEY LES GOUTTES