Drinking water quality in Loire-Authion
PFAS in drinking water
No PFAS results have been published for Loire-Authion yet. Testing has been required across the EU since January 2026. We will show the values here as soon as they come out.
"Not published" does not mean "not present". Without test results, no one can say how much PFAS is in this water.
Water report for Loire-Authion
Get the free water report for Loire-Authion, plus an alert whenever new official results are published.
Official assessment
The latest official test passed all quality requirements.
„Eau d'alimentation conforme aux limites de qualité et non conforme aux références de qualité pour la température.“
Show all 16 official measurements
| Parameter | Value | Limit | Status |
|---|---|---|---|
| Nitrate | 0.81 mg/L | ≤ 50 mg/L | within limit |
| Nitrite | <0,010 mg/L | ≤ 0.5 mg/L | within limit |
| Lead | 2.1 µg/L | ≤ 10 µg/L | within limit |
| Copper | 0.0441 mg(Cu)/L | ≤ 2 mg(Cu)/L | within limit |
| Nickel | 0.7 µg/L | ≤ 20 µg/L | within limit |
| Chromium | 0.3 µg/L | ≤ 50 µg/L | within limit |
| Escherichia coli | <1 n/(100mL) | ≤ 0 mL) | within limit |
| Enterococci | <1 n/(100mL) | ≤ 0 mL) | within limit |
| Coliform bacteria | <1 n/(100mL) | ≤ 0 mL) | within limit |
| pH | 8 unité pH | 6.5–9 unité pH | within limit |
| Water hardness | 29.3 °f | no limit | informational |
| Electrical conductivity | 1,030 µS/cm | 200–1,100 µS/cm | within limit |
| Chloride | 95.6 mg/L | ≤ 250 mg/L | within limit |
| Sulphate | 159 mg/L | ≤ 250 mg/L | within limit |
| Iron | 31 µg/L | ≤ 200 µg/L | within limit |
| Turbidity | <0,30 NFU | ≤ 2 NFU | within limit |
Frequently asked questions
Is tap water in Loire-Authion safe to drink?
Yes. The latest official test (1 June 2026) checked the tap water in Loire-Authion and it passed every requirement.
How high are PFAS levels in Loire-Authion's drinking water?
No PFAS results have been published for Loire-Authion yet. Testing has been required across the EU since January 2026. We will show the values here as soon as they come out.
How hard is the water in Loire-Authion?
The water hardness in Loire-Authion is 29.3 °f (medium). This mainly matters for household appliances and detergent dosing, not for health.
Where does this data come from?
All values come from official publications: Hub'eau, Qualité de l'eau potable (Ministère de la Santé / OFB / BRGM). Retrieved on 28 August 2026.
Data source
- Hub'eau, Qualité de l'eau potable (Ministère de la Santé / OFB / BRGM)
- https://hubeau.eaufrance.fr/api/v1/qualite_eau_potable/resultats_dis?code_commune=49307
- License
- Licence Ouverte / Open Licence (Etalab)
- Retrieved
- 28 August 2026
- Supply networks
- ANGERS, ANDARD, SAINT MATHURIN
This site is a data project, not an official source. If in doubt, check with your water supplier or local authority.