PFAS in Les Garennes sur Loire's tap water: under 3 ng/L, none of the four main PFAS detected

Last PFAS check: · Source: Hub'eau

PFAS in drinking water

None of the 4 most harmful PFAS detected

Amount found in the water < 3 ng/L the 4 most harmful PFAS (PFAS-4) · the lab's detection limit 20 PFAS looked for, 3.3 ng/L found in total
Our health benchmark 0.5 ng/L

The lab sees nothing below 3 ng/L, 6 times our benchmark of 0.5 ng/L. Water above our benchmark would pass this check unnoticed.

0.5 ng/L is our benchmark, not an official limit. Same EFSA method as Sweden, Denmark and the Netherlands, but stricter. It's a yearly average, compared here with the latest check.

Sample taken in Brissac Loire Aubance, on the same distribution network as Les Garennes sur Loire (SAINT REMY). The health authority samples one tap per network; a network carries the same treated water everywhere.

More about this result

The US also limits PFOA and PFOS to 4 ng/L each, per substance.

The lab detects each of the four substances from 0.5 to 1.5 ng/L upward. None reached that limit, so their total is below 3 ng/L rather than zero.

20 PFAS (see each substance)
PFAS substance Value
Acide sulfonique de perfluorobutane (PFBS) 0.0033 µg/L
Acide perfluorohexanoïque (PFHXA) <0,001 µg/L
Perfluorohexane sulfonate (PFHXS) <0,0005 µg/L
Acide perfluorononane sulfonique (PFNS) <0,001 µg/L
Acide perfluoro-nonanoïque (PFNA) <0,0005 µg/L
Acide perfluoro-octanoïque (PFOA) <0,0005 µg/L
Acide perfluorododécanoique (PFDoDA) <0,0015 µg/L
Acide perfluorododécane sulfonique (PFDoDS) <0,0015 µg/L
Acide perfluoropentanoïque (PFPEA) <0,0005 µg/L
Acide perfluoro tridecanoique (PFTrDA) <0,001 µg/L
Acide perfluoro undecane sulfonique (PFUnDS) <0,0015 µg/L
Acide perfluoroheptane sulfonique (PFHpS) <0,001 µg/L
Acide sulfonique de perfluorooctane (PFOS) <0,0015 µg/L
Acide perfluoro undecanoïque (PFUnA) <0,0015 µg/L
Acide perfluorodecane sulfonique (PFDS) <0,001 µg/L
Acide perfluoro tridecane sulfonique (PFTrDS) <0,0015 µg/L
Acide perfluoropentane sulfonique (PFPS) <0,001 µg/L
Acide perfluoro-decanoïque (PFDA) <0,0015 µg/L
Acide perfluorobutanoïque (PFBA) <0,0015 µg/L
Acide perfluoroheptanoïque (PFHPA) <0,001 µg/L

None found. The lab sees nothing below 3 ng/L, so our 0.5 ng/L benchmark cannot be checked.

EU legal limit
3.3 ng/L sum of 20 PFAS, below the 100 ng/L limit
Last PFAS test
18 February 2026
Water supplier
VEOLIA EAU CGE BRISSAC

In Les Garennes sur Loire, none of the 4 most closely watched PFAS (PFAS-4) was detected at the latest PFAS check on 18 February 2026. The total is below 3 ng/L, the sum of the detection limits and 6 times our 0.5 ng/L benchmark. Sum of 20 PFAS: 3.3 ng/L (0.0033 µg/L), below the EU legal limit (100 ng/L). Sampled in Brissac Loire Aubance, on the same network. 3 checks since 17 March 2025: sum of 20 PFAS up to 3.3 ng/L, sometimes below the detection limit. Source: Hub'eau, Qualité de l'eau potable (Ministère de la Santé / OFB / BRGM).

Details and sources
Water supplier: VEOLIA EAU CGE BRISSAC Latest water check: 3 July 2026 Data updated on

PFAS over time in Les Garennes sur Loire

3 PFAS checks since 17 March 2025, from the published measurements.

“Calculated”: PFAS-4 worked out from the four substances in the same sample. The chart, averages and trends use lab-published sums only.

3.3 ng/L017 March 202518 February 2026
Laboratory-published sum of 20 PFAS per check in ng/L. Hollow dots: below the detection limit. Calculated PFAS-4 values are listed in the table.
DatePFAS-4Sum of 20 PFASSampled at
< 3 ng/L · calculated3.3 ng/LBrissac Loire Aubance
< 3 ng/L · calculated2.7 ng/LBrissac Loire Aubance
< 10 ng/L · calculated< detection limitBrissac Loire Aubance

Calculated values: “<” is an upper bound from published thresholds, “≥” a lower bound, “–” means no published sum or complete measurement. How to read a PFAS result

What the latest check found

At the latest check, the water was within every limit tested.

Microbiology: within the limit Chemistry: within the limit
See all 17 test results
What was tested Value Limit Status
Nitrate 1.2 mg/L ≤ 50 mg/L within the limit
Nitrite <0,010 mg/L ≤ 0.5 mg/L within the limit
Lead 0.5 µg/L ≤ 10 µg/L within the limit
Copper 0.0058 mg(Cu)/L ≤ 2 mg(Cu)/L within the limit
Nickel 3 µg/L ≤ 20 µg/L within the limit
Cadmium 0.01 µg/L ≤ 5 µg/L within the limit
Chromium 0.4 µg/L ≤ 50 µg/L within the limit
Escherichia coli <1 n/(100mL) ≤ 0 mL) within the limit
Enterococci <1 n/(100mL) ≤ 0 mL) within the limit
Coliform bacteria <1 n/(100mL) ≤ 0 mL) within the limit
pH 7.8 unité pH 6.5–9 unité pH within the limit
Water hardness 18.7 °f no limit for reference
Electrical conductivity 535 µS/cm 200–1,100 µS/cm within the limit
Chloride 30.7 mg/L ≤ 250 mg/L within the limit
Sulphate 52.5 mg/L ≤ 250 mg/L within the limit
Iron 1 µg/L ≤ 200 µg/L within the limit
Turbidity <0,30 NFU ≤ 2 NFU within the limit

Frequently asked questions

Is tap water in Les Garennes sur Loire safe to drink?

Yes. At the check on 3 July 2026, the tap water in Les Garennes sur Loire was within every limit tested. “Eau d'alimentation conforme aux limites de qualité et non conforme aux références de qualité pour la température.”

How high are PFAS levels in Les Garennes sur Loire's drinking water?

The total of 20 PFAS ("forever chemicals") was last measured at 3.3 ng/L. The EU limit is 100 ng/L, so this water is at 3 % of the limit. (below the EU limit)

Does the water in Les Garennes sur Loire also meet the strictest limits in Europe?

As far as this check can tell, yes. None of the four compounds was quantified, so their total is below 3 ng/L, the sum of the laboratory's detection limits, and under Sweden's legal limit of 4 ng/L in force since 2026.

Are PFAS levels rising in Les Garennes sur Loire's tap water?

Calculated PFAS-4 values are listed in the table. The chart uses laboratory-published sum-of-20 results; there are too few laboratory-published PFAS-4 sums for the existing trend calculation.

How hard is the water in Les Garennes sur Loire?

The water hardness in Les Garennes sur Loire is 18.7 °f (medium). This mainly matters for household appliances and detergent dosing, not for health.

Where does this data come from?

All values come from official publications: Hub'eau, Qualité de l'eau potable (Ministère de la Santé / OFB / BRGM). Retrieved on 21 September 2026.

Same water network

Same distribution network as Les Garennes sur Loire, so in principle the same water.

Nearby communes

The closest to Les Garennes sur Loire on this site.

Data source

Hub'eau, Qualité de l'eau potable (Ministère de la Santé / OFB / BRGM)
https://hubeau.eaufrance.fr/api/v1/qualite_eau_potable/resultats_dis?code_commune=49167
License
Licence Ouverte / Open Licence (Etalab)
Retrieved
21 September 2026
Supply networks
JUIGNE SUR LOIRE, SAINT REMY

This site is a data project, not an official source. If in doubt, check with your water supplier or local authority.