PFAS in La Tour-du-Meix's tap water: under 4 ng/L, none of the four main PFAS detected

Last PFAS check: · Source: Hub'eau

PFAS in drinking water

No PFAS detected

Amount found in the water < 4 ng/L the 4 most harmful PFAS (PFAS-4) · the lab's detection limit 20 PFAS looked for, none found
Our health benchmark 0.5 ng/L

The lab sees nothing below 4 ng/L, 8 times our benchmark of 0.5 ng/L. Water above our benchmark would pass this check unnoticed.

0.5 ng/L is our benchmark, not an official limit. Same EFSA method as Sweden, Denmark and the Netherlands, but stricter. It's a yearly average, compared here with the latest check.

Sample taken in Orgelet, on the same distribution network as La Tour-du-Meix (LA TOUR DU MEIX). The health authority samples one tap per network; a network carries the same treated water everywhere.

More about this result

The US also limits PFOA and PFOS to 4 ng/L each, per substance.

The lab detects each of the four substances from 1 ng/L upward. None reached that limit, so their total is below 4 ng/L rather than zero.

20 PFAS (see each substance)
PFAS substance Value
Acide perfluoropentanoïque (PFPEA) <0,001 µg/L
Acide perfluorohexanoïque (PFHXA) <0,002 µg/L
Acide perfluoroheptane sulfonique (PFHpS) <0,002 µg/L
Acide perfluoroheptanoïque (PFHPA) <0,001 µg/L
Perfluorohexane sulfonate (PFHXS) <0,001 µg/L
Acide perfluoro undecanoïque (PFUnA) <0,001 µg/L
Acide perfluoro-octanoïque (PFOA) <0,001 µg/L
Acide perfluoro-decanoïque (PFDA) <0,001 µg/L
Acide perfluoro tridecanoique (PFTrDA) <0,001 µg/L
Acide sulfonique de perfluorooctane (PFOS) <0,001 µg/L
Acide perfluoropentane sulfonique (PFPS) <0,001 µg/L
Acide perfluoro undecane sulfonique (PFUnDS) <0,002 µg/L
Acide sulfonique de perfluorobutane (PFBS) <0,001 µg/L
Acide perfluorodecane sulfonique (PFDS) <0,001 µg/L
Acide perfluorododécanoique (PFDoDA) <0,001 µg/L
Acide perfluorobutanoïque (PFBA) <0,002 µg/L
Acide perfluoro tridecane sulfonique (PFTrDS) <0,005 µg/L
Acide perfluoro-nonanoïque (PFNA) <0,001 µg/L
Acide perfluorononane sulfonique (PFNS) <0,002 µg/L
Acide perfluorododécane sulfonique (PFDoDS) <0,001 µg/L

None found. The lab sees nothing below 4 ng/L, so our 0.5 ng/L benchmark cannot be checked.

EU legal limit
none detected sum of 20 PFAS below the detection limit, limit 100 ng/L
Last PFAS test
28 April 2026
Water supplier
S.O.G.E.D.O. SAINT LAURENT

In La Tour-du-Meix, none of the 4 most closely watched PFAS (PFAS-4) was detected at the latest PFAS check on 28 April 2026. The total is below 4 ng/L, the sum of the detection limits and 8 times our 0.5 ng/L benchmark. Sum of 20 PFAS: <0,029 µg/L, below the EU legal limit (100 ng/L). Sampled in Orgelet, on the same network. 3 checks since 8 October 2025, PFAS-4 always below the detection limit (4 ng/L). Source: Hub'eau, Qualité de l'eau potable (Ministère de la Santé / OFB / BRGM).

Details and sources
Water supplier: S.O.G.E.D.O. SAINT LAURENT Latest water check: 8 June 2026 Data updated on

PFAS over time in La Tour-du-Meix

4 PFAS checks since 10 March 2025, from the published measurements. Samples from 2 communes on the same network: it's the same water, so each one applies to La Tour-du-Meix. Samples come from 2 distribution networks. The trend refers to the network “SIAEP REGION DE VOUGLANS”.

“Calculated”: PFAS-4 worked out from the four substances in the same sample. The chart, averages and trends use lab-published sums only.

DatePFAS-4Sum of 20 PFASSampled atNetwork
< 4 ng/L< 29 ng/LOrgeletLA TOUR DU MEIX, SIAEP REGION DE VOUGLANS
< 4 ng/L< 29 ng/LPont-de-PoitteSIAEP REGION DE VOUGLANS
< 4 ng/L< 29 ng/LPont-de-PoitteSIAEP REGION DE VOUGLANS
< 4 ng/L · calculated< 100 ng/LPont-de-PoitteSIAEP REGION DE VOUGLANS

Calculated values: “<” is an upper bound from published thresholds, “≥” a lower bound, “–” means no published sum or complete measurement. How to read a PFAS result

What the latest check found

At the latest check, the water was within every limit tested.

Microbiology: within the limit Chemistry: within the limit
See all 16 test results
What was tested Value Limit Status
Nitrate 3.5 mg/L ≤ 50 mg/L within the limit
Nitrite 0 mg/L ≤ 0.5 mg/L within the limit
Lead <2 µg/L ≤ 10 µg/L within the limit
Copper 0.093 mg(Cu)/L ≤ 2 mg(Cu)/L within the limit
Nickel <5 µg/L ≤ 20 µg/L within the limit
Cadmium <1 µg/L ≤ 5 µg/L within the limit
Chromium <5 µg/L ≤ 50 µg/L within the limit
Escherichia coli <1 n/(100mL) ≤ 0 mL) within the limit
Enterococci <1 n/(100mL) ≤ 0 mL) within the limit
Coliform bacteria <1 n/(100mL) ≤ 0 mL) within the limit
pH 7.5 unité pH 6.5–9 unité pH within the limit
Water hardness 26.5 °f no limit for reference
Electrical conductivity 493 µS/cm 200–1,100 µS/cm within the limit
Chloride 2.9 mg/L ≤ 250 mg/L within the limit
Sulphate 5.8 mg/L ≤ 250 mg/L within the limit
Turbidity 0.44 NFU ≤ 2 NFU within the limit

Frequently asked questions

Is tap water in La Tour-du-Meix safe to drink?

Yes. At the check on 8 June 2026, the tap water in La Tour-du-Meix was within every limit tested. “Eau d'alimentation conforme aux exigences de qualité en vigueur pour l'ensemble des paramètres mesurés.”

How high are PFAS levels in La Tour-du-Meix's drinking water?

At the latest check the total of 20 PFAS ("forever chemicals") was below the laboratory's reporting limit of 29 ng/L. The EU limit is 100 ng/L, so this water is under 29 % of the limit. (below the EU limit)

Does the water in La Tour-du-Meix also meet the strictest limits in Europe?

As far as this check can tell, yes. None of the four compounds was quantified, so their total is below 4 ng/L, the sum of the laboratory's detection limits, and under Sweden's legal limit of 4 ng/L in force since 2026.

Are PFAS levels rising in La Tour-du-Meix's tap water?

No. Since 10 March 2025, 3 checks have been published and the PFAS-4 sum stayed below the laboratory's detection limit (4 ng/L) every time. These history statistics use laboratory-published sums only.

How hard is the water in La Tour-du-Meix?

The water hardness in La Tour-du-Meix is 26.5 °f (medium). This mainly matters for household appliances and detergent dosing, not for health.

Where does this data come from?

All values come from official publications: Hub'eau, Qualité de l'eau potable (Ministère de la Santé / OFB / BRGM). Retrieved on 12 September 2026.

Same water network

Same distribution network as La Tour-du-Meix, so in principle the same water.

Nearby communes

The closest to La Tour-du-Meix on this site.

Data source

Hub'eau, Qualité de l'eau potable (Ministère de la Santé / OFB / BRGM)
https://hubeau.eaufrance.fr/api/v1/qualite_eau_potable/resultats_dis?code_commune=39534
License
Licence Ouverte / Open Licence (Etalab)
Retrieved
12 September 2026
Supply networks
LA TOUR DU MEIX, SIAEP REGION DE VOUGLANS