PFAS in the tap water of La Celle (Allier): under 4 ng/L, none of the four main PFAS detected

Last PFAS check: · Source: Hub'eau

PFAS in drinking water

None of the 4 most harmful PFAS detected

Amount found in the water < 4 ng/L the 4 most harmful PFAS (PFAS-4) · the lab's detection limit 20 PFAS looked for, 10 ng/L found in total
Our health benchmark 0.5 ng/L

The lab sees nothing below 4 ng/L, 8 times our benchmark of 0.5 ng/L. Water above our benchmark would pass this check unnoticed.

0.5 ng/L is our benchmark, not an official limit. Same EFSA method as Sweden, Denmark and the Netherlands, but stricter. It's a yearly average, compared here with the latest check.

Sample taken in Terjat, on the same distribution network as La Celle (RES. ARPHEUILLES-RONNET-TERJAT). The health authority samples one tap per network; a network carries the same treated water everywhere.

More about this result

The US also limits PFOA and PFOS to 4 ng/L each, per substance.

The lab detects each of the four substances from 1 ng/L upward. None reached that limit, so their total is below 4 ng/L rather than zero.

20 PFAS (see each substance)
PFAS substance Value
Acide perfluorohexanoïque (PFHXA) 0.007 µg/L
Acide perfluoroheptanoïque (PFHPA) 0.002 µg/L
Acide perfluoropentanoïque (PFPEA) 0.001 µg/L
Acide perfluoroheptane sulfonique (PFHpS) <0,002 µg/L
Acide sulfonique de perfluorobutane (PFBS) <0,001 µg/L
Acide perfluorodecane sulfonique (PFDS) <0,001 µg/L
Acide perfluoro undecanoïque (PFUnA) <0,001 µg/L
Acide perfluoro tridecanoique (PFTrDA) <0,001 µg/L
Acide perfluoro tridecane sulfonique (PFTrDS) <0,005 µg/L
Acide perfluoro-decanoïque (PFDA) <0,001 µg/L
Perfluorohexane sulfonate (PFHXS) <0,001 µg/L
Acide sulfonique de perfluorooctane (PFOS) <0,001 µg/L
Acide perfluorobutanoïque (PFBA) <0,002 µg/L
Acide perfluorononane sulfonique (PFNS) <0,002 µg/L
Acide perfluoro undecane sulfonique (PFUnDS) <0,002 µg/L
Acide perfluorododécanoique (PFDoDA) <0,001 µg/L
Acide perfluoro-octanoïque (PFOA) <0,001 µg/L
Acide perfluorododécane sulfonique (PFDoDS) <0,001 µg/L
Acide perfluoro-nonanoïque (PFNA) <0,001 µg/L
Acide perfluoropentane sulfonique (PFPS) <0,001 µg/L

None found. The lab sees nothing below 4 ng/L, so our 0.5 ng/L benchmark cannot be checked.

EU legal limit
10 ng/L sum of 20 PFAS, below the 100 ng/L limit
Last PFAS test
28 May 2026
Water supplier
SIVOM REGION MINIERE

In La Celle, none of the 4 most closely watched PFAS (PFAS-4) was detected at the latest PFAS check on 28 May 2026. The total is below 4 ng/L, the sum of the detection limits and 8 times our 0.5 ng/L benchmark. Sum of 20 PFAS: 10 ng/L (0.01 µg/L), below the EU legal limit (100 ng/L). Sampled in Terjat, on the same network. 4 checks since 2 September 2025, PFAS-4 always below the detection limit (4 ng/L). Source: Hub'eau, Qualité de l'eau potable (Ministère de la Santé / OFB / BRGM).

Details and sources
Water supplier: SIVOM REGION MINIERE Latest water check: 28 May 2026 Data updated on

PFAS over time in La Celle

7 PFAS checks since 2 April 2025, from the published measurements. Samples from 5 communes on the same network: it's the same water, so each one applies to La Celle. Samples come from 2 distribution networks. The trend refers to the network “RESEAU PRAT - REGION MINIERE”.

“Calculated”: PFAS-4 worked out from the four substances in the same sample. The chart, averages and trends use lab-published sums only.

DatePFAS-4Sum of 20 PFASSampled atNetwork
< 4 ng/L10 ng/LTerjatRES. ARPHEUILLES-RONNET-TERJAT
< 4 ng/L< 29 ng/LSaint-AngelRESEAU PRAT - REGION MINIERE
< 4 ng/L5 ng/LArpheuilles-Saint-PriestRES. ARPHEUILLES-RONNET-TERJAT
< 4 ng/L4 ng/LQuinssainesRESEAU PRAT - REGION MINIERE
< 4 ng/L · calculated2 ng/LSainte-ThérenceRESEAU PRAT - REGION MINIERE
< 4 ng/L · calculated2 ng/LQuinssainesRESEAU PRAT - REGION MINIERE
< 4 ng/L · calculated< 100 ng/LSainte-ThérenceRESEAU PRAT - REGION MINIERE

Calculated values: “<” is an upper bound from published thresholds, “≥” a lower bound, “–” means no published sum or complete measurement. How to read a PFAS result

What the latest check found

At the latest check, the water was within every limit tested.

Microbiology: within the limit Chemistry: within the limit
See all 17 test results
What was tested Value Limit Status
Nitrate 19.2 mg/L ≤ 50 mg/L within the limit
Nitrite <0,01 mg/L ≤ 0.5 mg/L within the limit
Lead <2 µg/L ≤ 10 µg/L within the limit
Copper 0.174 mg/L ≤ 2 mg/L within the limit
Nickel <5 µg/L ≤ 20 µg/L within the limit
Cadmium <1 µg/L ≤ 5 µg/L within the limit
Chromium <5 µg/L ≤ 50 µg/L within the limit
Escherichia coli <1 n/(100mL) ≤ 0 mL) within the limit
Enterococci <1 n/(100mL) ≤ 0 mL) within the limit
Coliform bacteria <1 n/(100mL) ≤ 0 mL) within the limit
pH 8.1 unité pH 6.5–9 unité pH within the limit
Water hardness 15.63 °f no limit for reference
Electrical conductivity 365 µS/cm 200–1,100 µS/cm within the limit
Chloride 12.4 mg/L ≤ 250 mg/L within the limit
Sulphate 23.4 mg/L ≤ 250 mg/L within the limit
Iron <10 µg/L ≤ 200 µg/L within the limit
Turbidity <0,1 NFU ≤ 2 NFU within the limit

Frequently asked questions

Is tap water in La Celle safe to drink?

Yes. At the check on 28 May 2026, the tap water in La Celle was within every limit tested. “Eau conforme aux limites et aux références de qualité pour ce qui concerne les paramètres mesurés.”

How high are PFAS levels in La Celle's drinking water?

The total of 20 PFAS ("forever chemicals") was last measured at 10 ng/L. The EU limit is 100 ng/L, so this water is at 10 % of the limit. (below the EU limit)

Does the water in La Celle also meet the strictest limits in Europe?

As far as this check can tell, yes. None of the four compounds was quantified, so their total is below 4 ng/L, the sum of the laboratory's detection limits, and under Sweden's legal limit of 4 ng/L in force since 2026.

Are PFAS levels rising in La Celle's tap water?

Too few quantified checks to say (0 since 2 April 2025). pfasnearme adds each new publication weekly; a trend needs at least three quantified values. These history statistics use laboratory-published sums only.

How hard is the water in La Celle?

The water hardness in La Celle is 15.6 °f (medium). This mainly matters for household appliances and detergent dosing, not for health.

Where does this data come from?

All values come from official publications: Hub'eau, Qualité de l'eau potable (Ministère de la Santé / OFB / BRGM). Retrieved on 21 September 2026.

Same water network

Same distribution network as La Celle, so in principle the same water.

Nearby communes

The closest to La Celle on this site.

Data source

Hub'eau, Qualité de l'eau potable (Ministère de la Santé / OFB / BRGM)
https://hubeau.eaufrance.fr/api/v1/qualite_eau_potable/resultats_dis?code_commune=03047
License
Licence Ouverte / Open Licence (Etalab)
Retrieved
21 September 2026
Supply networks
RES. ARPHEUILLES-RONNET-TERJAT, RESEAU PRAT - REGION MINIERE

This site is a data project, not an official source. If in doubt, check with your water supplier or local authority.