Drinking water quality in Génissieux
PFAS in drinking water
No PFAS results have been published for Génissieux yet. Testing has been required across the EU since January 2026. We will show the values here as soon as they come out.
"Not published" does not mean "not present". Without test results, no one can say how much PFAS is in this water.
Water report for Génissieux
Get the free water report for Génissieux, plus an alert whenever new official results are published.
Official assessment
The latest official test passed all quality requirements.
„Eau d'alimentation conforme aux limites de qualité en vigueur. La réfé rence de qualité fixée à 25°C pour la température est dépassée. Ce par amètre n'est représentatif que du lieu de prélèvement.“
Show all 17 official measurements
| Parameter | Value | Limit | Status |
|---|---|---|---|
| Nitrate | 1.9 mg/L | ≤ 50 mg/L | within limit |
| Nitrite | 0.01 mg/L | ≤ 0.5 mg/L | within limit |
| Lead | <2 µg/L | ≤ 10 µg/L | within limit |
| Copper | 0.063 mg(Cu)/L | ≤ 2 mg(Cu)/L | within limit |
| Nickel | <5 µg/L | ≤ 20 µg/L | within limit |
| Cadmium | <1 µg/L | ≤ 5 µg/L | within limit |
| Chromium | <5 µg/L | ≤ 50 µg/L | within limit |
| Escherichia coli | <1 n/(100mL) | ≤ 0 mL) | within limit |
| Enterococci | <1 n/(100mL) | ≤ 0 mL) | within limit |
| Coliform bacteria | <1 n/(100mL) | ≤ 0 mL) | within limit |
| pH | 7.5 unité pH | 6.5–9 unité pH | within limit |
| Water hardness | 26.81 °f | no limit | informational |
| Electrical conductivity | 543 µS/cm | 200–1,100 µS/cm | within limit |
| Chloride | 1.4 mg/L | ≤ 250 mg/L | within limit |
| Sulphate | 13.1 mg/L | ≤ 250 mg/L | within limit |
| Iron | <10 µg/L | ≤ 200 µg/L | within limit |
| Turbidity | <0,1 NFU | ≤ 2 NFU | within limit |
Frequently asked questions
Is tap water in Génissieux safe to drink?
Yes. The latest official test (22 June 2026) checked the tap water in Génissieux and it passed every requirement.
How high are PFAS levels in Génissieux's drinking water?
No PFAS results have been published for Génissieux yet. Testing has been required across the EU since January 2026. We will show the values here as soon as they come out.
How hard is the water in Génissieux?
The water hardness in Génissieux is 26.81 °f (medium). This mainly matters for household appliances and detergent dosing, not for health.
Where does this data come from?
All values come from official publications: Hub'eau, Qualité de l'eau potable (Ministère de la Santé / OFB / BRGM). Retrieved on 28 August 2026.
Data source
- Hub'eau, Qualité de l'eau potable (Ministère de la Santé / OFB / BRGM)
- https://hubeau.eaufrance.fr/api/v1/qualite_eau_potable/resultats_dis?code_commune=26139
- License
- Licence Ouverte / Open Licence (Etalab)
- Retrieved
- 28 August 2026
- Supply networks
- S HERBASSE CHATILLON
This site is a data project, not an official source. If in doubt, check with your water supplier or local authority.