PFAS in Crissay-sur-Manse's tap water: under 10 ng/L, none of the four main PFAS detected
Last PFAS check: · Source: Hub'eau
PFAS in drinking water
No PFAS detected
The lab sees nothing below 10 ng/L, 20 times our benchmark of 0.5 ng/L. Water above our benchmark would pass this check unnoticed.
0.5 ng/L is our benchmark, not an official limit. Same EFSA method as Sweden, Denmark and the Netherlands, but stricter. It's a yearly average, compared here with the latest check.
Sample taken in Saint-Épain, on the same distribution network as Crissay-sur-Manse (ST EPAIN). The health authority samples one tap per network; a network carries the same treated water everywhere.
More about this result
The US also limits PFOA and PFOS to 4 ng/L each, per substance.
The lab detects each of the four substances from 2 to 4 ng/L upward. None reached that limit, so their total is below 10 ng/L rather than zero.
checked on 17 June 2025
20 PFAS (see each substance)
| PFAS substance | Value |
|---|---|
| Acide perfluoro undecanoïque (PFUnA) | <0,002 µg/L |
| Acide perfluoro-decanoïque (PFDA) | <0,002 µg/L |
| Acide sulfonique de perfluorooctane (PFOS) | <0,004 µg/L |
| Acide sulfonique de perfluorobutane (PFBS) | <0,010 µg/L |
| Acide perfluorobutanoïque (PFBA) | <0,020 µg/L |
| Acide perfluorodecane sulfonique (PFDS) | <0,002 µg/L |
| Acide perfluoroheptanoïque (PFHPA) | <0,002 µg/L |
| Acide perfluoro undecane sulfonique (PFUnDS) | <0,004 µg/L |
| Acide perfluorononane sulfonique (PFNS) | <0,002 µg/L |
| Perfluorohexane sulfonate (PFHXS) | <0,002 µg/L |
| Acide perfluoro tridecanoique (PFTrDA) | <0,002 µg/L |
| Acide perfluorododécanoique (PFDoDA) | <0,002 µg/L |
| Acide perfluorohexanoïque (PFHXA) | <0,010 µg/L |
| Acide perfluoro-nonanoïque (PFNA) | <0,002 µg/L |
| Acide perfluorododécane sulfonique (PFDoDS) | <0,002 µg/L |
| Acide perfluoropentanoïque (PFPEA) | <0,010 µg/L |
| Acide perfluoropentane sulfonique (PFPS) | <0,004 µg/L |
| Acide perfluoro tridecane sulfonique (PFTrDS) | <0,004 µg/L |
| Acide perfluoro-octanoïque (PFOA) | <0,002 µg/L |
| Acide perfluoroheptane sulfonique (PFHpS) | <0,004 µg/L |
None found. The lab sees nothing below 10 ng/L, so our 0.5 ng/L benchmark cannot be checked.
Water report for Crissay-sur-Manse
Get new PFAS results for Crissay-sur-Manse, with a short explanation. At most one update a week, only when there's something new.
- EU legal limit
- none detected sum of 20 PFAS below the detection limit, limit 100 ng/L
- Last PFAS test
- 17 June 2025
- Water supplier
- S.A.U.R. FRANCE
In Crissay-sur-Manse, none of the 4 most closely watched PFAS (PFAS-4) was detected at the latest PFAS check on 17 June 2025. The total is below 10 ng/L, the sum of the detection limits and 20 times our 0.5 ng/L benchmark. Sum of 20 PFAS: <SEUIL µg/L, below the EU legal limit (100 ng/L). Sampled in Saint-Épain, on the same network. Source: Hub'eau, Qualité de l'eau potable (Ministère de la Santé / OFB / BRGM).
Details and sources
PFAS over time in Crissay-sur-Manse
A single PFAS check has been published for Crissay-sur-Manse so far (17 June 2025). A history will build up with the next checks; this page is refreshed weekly.
What the latest check found
At the latest check, the water was within every limit tested.
Values to watch
These results are close to their legal limit, or over it.
Outside a reference value: Electrical conductivity 1,328 µS/cm on 30 March 2026 (reference 180–1,000 µS/cm). These are indicator parameters with reference values, not legal limits.
| What was tested | Value | Limit | Status |
|---|---|---|---|
| Fluoride | 1.106 mg/L | ≤ 1.5 mg/L | within the limit |
| Electrical conductivity | 1,328 µS/cm | 180–1,000 µS/cm | above the reference value |
See all 19 test results
| What was tested | Value | Limit | Status |
|---|---|---|---|
| Nitrate | 3.2 mg/L | ≤ 50 mg/L | within the limit |
| Nitrite | <0,010 mg/L | ≤ 0.5 mg/L | within the limit |
| Lead | 0.6 µg/L | ≤ 10 µg/L | within the limit |
| Copper | 0.0832 mg(Cu)/L | ≤ 2 mg(Cu)/L | within the limit |
| Nickel | 7.5 µg/L | ≤ 20 µg/L | within the limit |
| Cadmium | 0.033 µg/L | ≤ 5 µg/L | within the limit |
| Chromium | 0.6 µg/L | ≤ 50 µg/L | within the limit |
| Fluoride | 1.106 mg/L | ≤ 1.5 mg/L | within the limit |
| Escherichia coli | <1 n/(100mL) | ≤ 0 mL) | within the limit |
| Enterococci | <1 n/(100mL) | ≤ 0 mL) | within the limit |
| Coliform bacteria | <1 n/(100mL) | ≤ 0 mL) | within the limit |
| pH | 7.4 unité pH | 6.5–9 unité pH | within the limit |
| Water hardness | 31.4 °f | no limit | for reference |
| Electrical conductivity | 1,328 µS/cm | 180–1,000 µS/cm | above the reference value |
| Chloride | 244 mg/L | ≤ 250 mg/L | within the limit |
| Sulphate | 153 mg/L | ≤ 250 mg/L | within the limit |
| Sodium | 174 mg/L | ≤ 200 mg/L | within the limit |
| Iron | 21 µg/L | ≤ 200 µg/L | within the limit |
| Turbidity | <0,30 NFU | ≤ 2 NFU | within the limit |
Frequently asked questions
Is tap water in Crissay-sur-Manse safe to drink?
Yes. At the check on 30 March 2026, the tap water in Crissay-sur-Manse was within every limit tested. Outside a reference value: Electrical conductivity 1,328 µS/cm on 30 March 2026 (reference 180–1,000 µS/cm). These are indicator parameters with reference values, not legal limits. “Eau d'alimentation conforme aux limites de qualité et non conforme aux références de qualité pour le paramètre conductivité (mesure la quantité de minéraux dissous de l'eau). Cette situation a pour origine la nature de la ressource exploitée (nappe du cénomanien) et ne présente pas un danger pour la santé des consommateurs.”
How high are PFAS levels in Crissay-sur-Manse's drinking water?
The total of 20 PFAS ("forever chemicals") was last measured at –. The EU limit is 100 ng/L, so this water is at – of the limit. (below the EU limit)
Does the water in Crissay-sur-Manse also meet the strictest limits in Europe?
The check cannot say. None of the four compounds was quantified, but the laboratory's detection limits add up to 10 ng/L, above Sweden's legal limit of 4 ng/L in force since 2026, so a value between the two would go unnoticed.
How hard is the water in Crissay-sur-Manse?
The water hardness in Crissay-sur-Manse is 31.4 °f (hard). This mainly matters for household appliances and detergent dosing, not for health.
Where does this data come from?
All values come from official publications: Hub'eau, Qualité de l'eau potable (Ministère de la Santé / OFB / BRGM). Retrieved on 12 September 2026.
Same water network
Same distribution network as Crissay-sur-Manse, so in principle the same water.
Nearby communes
The closest to Crissay-sur-Manse on this site.
Data source
- Hub'eau, Qualité de l'eau potable (Ministère de la Santé / OFB / BRGM)
- https://hubeau.eaufrance.fr/api/v1/qualite_eau_potable/resultats_dis?code_commune=37090
- License
- Licence Ouverte / Open Licence (Etalab)
- Retrieved
- 12 September 2026
- Supply networks
- ST EPAIN
This site is a data project, not an official source. If in doubt, check with your water supplier or local authority.