PFAS in the tap water of Châtenay (Saône-et-Loire): 14 ng/L, 28x our 0.5 ng/L benchmark

Last PFAS check: · Source: Hub'eau

PFAS in drinking water

28× above our health benchmark

Amount found in the water 14 ng/L 0.014 µg/L · the 4 most harmful PFAS (PFAS-4)
Our health benchmark 0.5 ng/L

0.5 ng/L is our benchmark, not an official limit. Same EFSA method as Sweden, Denmark and the Netherlands, but stricter. It's a yearly average, compared here with the latest check.

Sample taken in Amanzé, on the same distribution network as Châtenay (BRIONNAIS-VINDECY-BAUGY). The health authority samples one tap per network; a network carries the same treated water everywhere.

More about this result

The US also limits PFOA and PFOS to 4 ng/L each, per substance.

Substances below the detection limit count as 0, so the real total may be higher.

One of these four, PFOA, is classified as causing cancer in humans by the WHO's cancer research agency (IARC).

More PFAS than in 97% of the cities we track

20 PFAS (see each substance)
PFAS substance Value
Acide sulfonique de perfluorooctane (PFOS) 0.011 µg/L
Perfluorohexane sulfonate (PFHXS) 0.003 µg/L
Acide perfluoro-decanoïque (PFDA) <0,001 µg/L
Acide perfluorononane sulfonique (PFNS) <0,002 µg/L
Acide perfluoropentanoïque (PFPEA) <0,001 µg/L
Acide perfluoro tridecanoique (PFTrDA) <0,001 µg/L
Acide perfluoro undecane sulfonique (PFUnDS) <0,002 µg/L
Acide sulfonique de perfluorobutane (PFBS) <0,001 µg/L
Acide perfluoro-octanoïque (PFOA) <0,001 µg/L
Acide perfluorobutanoïque (PFBA) <0,002 µg/L
Acide perfluoro undecanoïque (PFUnA) <0,001 µg/L
Acide perfluorododécanoique (PFDoDA) <0,001 µg/L
Acide perfluorododécane sulfonique (PFDoDS) <0,001 µg/L
Acide perfluoroheptane sulfonique (PFHpS) <0,002 µg/L
Acide perfluoro-nonanoïque (PFNA) <0,001 µg/L
Acide perfluoro tridecane sulfonique (PFTrDS) <0,005 µg/L
Acide perfluorohexanoïque (PFHXA) <0,002 µg/L
Acide perfluoroheptanoïque (PFHPA) <0,001 µg/L
Acide perfluorodecane sulfonique (PFDS) <0,001 µg/L
Acide perfluoropentane sulfonique (PFPS) <0,001 µg/L

Above our health benchmark. Here are some filter options.

EU legal limit
14 ng/L sum of 20 PFAS, below the 100 ng/L limit
Last PFAS test
9 March 2026
Water supplier
VEOLIA EAU - CHARLIEU

In Châtenay, the 4 most closely watched PFAS (PFAS-4) add up to 14 ng/L (0.014 µg/L) at the latest PFAS check on 9 March 2026. That's 28 times our 0.5 ng/L health benchmark, and above Sweden's legal limit of 4 ng/L. Sum of 20 PFAS: 14 ng/L (0.014 µg/L), below the EU legal limit (100 ng/L). Sampled in Amanzé, on the same network. 3 checks since 19 January 2026: PFAS-4 from 2 ng/L to 14 ng/L, averaging 8 ng/L over 12 months. Rising on the main network. Source: Hub'eau, Qualité de l'eau potable (Ministère de la Santé / OFB / BRGM).

Details and sources
Water supplier: VEOLIA EAU - CHARLIEU Latest water check: 16 June 2026 Data updated on

PFAS over time in Châtenay

3 PFAS checks since 19 January 2026, values as published. Samples from 3 communes on the same network: it's the same water, so each one applies to Châtenay.

0.5 ng/L14 ng/L019 January 20269 March 2026
PFAS-4 sum per check in ng/L. Dashed line: pfasnearme's 0.5 ng/L benchmark. Hollow dots: below the detection limit.
DatePFAS-4Sum of 20 PFASSampled at
14 ng/L14 ng/LAmanzé
2 ng/L2 ng/LPoisson
8 ng/L8 ng/LAnzy-le-Duc

“<” means not detected, the figure being the detection limit. “–” means not published. Labs have only reported the PFAS-4 sum (SANDRE code 9268) since autumn 2025. How to read a PFAS result

What the latest check found

At the latest check, the water was within every limit tested.

Microbiology: within the limit Chemistry: within the limit
See all 16 test results
What was tested Value Limit Status
Nitrate 13.4 mg/L ≤ 50 mg/L within the limit
Nitrite <0,01 mg/L ≤ 0.5 mg/L within the limit
Lead <2 µg/L ≤ 10 µg/L within the limit
Copper 0.015 mg/L ≤ 2 mg/L within the limit
Nickel <5 µg/L ≤ 20 µg/L within the limit
Cadmium <1 µg/L ≤ 5 µg/L within the limit
Chromium <5 µg/L ≤ 50 µg/L within the limit
Escherichia coli <1 n/(100mL) ≤ 0 mL) within the limit
Enterococci <1 n/(100mL) ≤ 0 mL) within the limit
Coliform bacteria <1 n/(100mL) ≤ 0 mL) within the limit
pH 7.2 unité pH 6.5–9 unité pH within the limit
Water hardness 16.63 °f no limit for reference
Electrical conductivity 382 µS/cm 200–1,100 µS/cm within the limit
Chloride 13.6 mg/L ≤ 250 mg/L within the limit
Sulphate 15 mg/L ≤ 250 mg/L within the limit
Turbidity 0.12 NFU ≤ 2 NFU within the limit

Frequently asked questions

Is tap water in Châtenay safe to drink?

Yes. At the check on 16 June 2026, the tap water in Châtenay was within every limit tested. “Eau d'alimentation conforme aux exigences de qualité en vigueur pour l'ensemble des paramètres mesurés.”

How high are PFAS levels in Châtenay's drinking water?

The total of 20 PFAS ("forever chemicals") was last measured at 14 ng/L. The EU limit is 100 ng/L, so this water is at 14 % of the limit. (below the EU limit)

Does the water in Châtenay also meet the strictest limits in Europe?

No. The four most harmful PFAS add up to 14 ng/L. That is 3.5 times Sweden's legal limit of 4 ng/L, in force since 2026. Germany will set a similar one in 2028. The water still passes the current EU legal limit (100 ng/L for the total of 20 PFAS).

Are PFAS levels rising in Châtenay's tap water?

Yes. On the main network, the PFAS-4 sum rose from 8 ng/L (19 January 2026) to 14 ng/L (9 March 2026) across 3 quantified checks. pfasnearme's benchmark is 0.5 ng/L as an annual mean.

How hard is the water in Châtenay?

The water hardness in Châtenay is 16.6 °f (medium). This mainly matters for household appliances and detergent dosing, not for health.

Where does this data come from?

All values come from official publications: Hub'eau, Qualité de l'eau potable (Ministère de la Santé / OFB / BRGM). Retrieved on 12 September 2026.

Same water network

Same distribution network as Châtenay, so in principle the same water.

Nearby communes

The closest to Châtenay on this site.

Data source

Hub'eau, Qualité de l'eau potable (Ministère de la Santé / OFB / BRGM)
https://hubeau.eaufrance.fr/api/v1/qualite_eau_potable/resultats_dis?code_commune=71116
License
Licence Ouverte / Open Licence (Etalab)
Retrieved
12 September 2026
Supply networks
BRIONNAIS-VINDECY-BAUGY

This site is a data project, not an official source. If in doubt, check with your water supplier or local authority.