PFAS in the tap water of Bouvron (Meurthe-et-Moselle): under 8 ng/L, none of the four main PFAS detected

Last PFAS check: · Source: Hub'eau

PFAS in drinking water

No PFAS detected

Amount found in the water < 8 ng/L the 4 most harmful PFAS (PFAS-4) · the lab's detection limit 20 PFAS looked for, none found
Our health benchmark 0.5 ng/L

The lab sees nothing below 8 ng/L, 16 times our benchmark of 0.5 ng/L. Water above our benchmark would pass this check unnoticed.

0.5 ng/L is our benchmark, not an official limit. Same EFSA method as Sweden, Denmark and the Netherlands, but stricter. It's a yearly average, compared here with the latest check.

More about this result

The US also limits PFOA and PFOS to 4 ng/L each, per substance.

The lab detects each of the four substances from 2 ng/L upward. None reached that limit, so their total is below 8 ng/L rather than zero.

20 PFAS (see each substance)
PFAS substance Value
Acide perfluoro undecanoïque (PFUnA) <0,002 µg/L
Acide perfluoro tridecane sulfonique (PFTrDS) <0,005 µg/L
Acide perfluorohexanoïque (PFHXA) <0,005 µg/L
Acide perfluorodecane sulfonique (PFDS) <0,002 µg/L
Acide perfluorododécane sulfonique (PFDoDS) <0,002 µg/L
Acide perfluoroheptane sulfonique (PFHpS) <0,002 µg/L
Acide perfluoro tridecanoique (PFTrDA) <0,002 µg/L
Acide perfluoro-decanoïque (PFDA) <0,002 µg/L
Acide perfluoropentane sulfonique (PFPS) <0,002 µg/L
Acide perfluorododécanoique (PFDoDA) <0,002 µg/L
Acide sulfonique de perfluorobutane (PFBS) <0,002 µg/L
Acide perfluoro undecane sulfonique (PFUnDS) <0,002 µg/L
Acide perfluorobutanoïque (PFBA) <0,005 µg/L
Acide perfluoropentanoïque (PFPEA) <0,005 µg/L
Acide perfluoro-nonanoïque (PFNA) <0,002 µg/L
Acide perfluoro-octanoïque (PFOA) <0,002 µg/L
Acide perfluoroheptanoïque (PFHPA) <0,002 µg/L
Acide perfluorononane sulfonique (PFNS) <0,002 µg/L
Perfluorohexane sulfonate (PFHXS) <0,002 µg/L
Acide sulfonique de perfluorooctane (PFOS) <0,002 µg/L

None found. The lab sees nothing below 8 ng/L, so our 0.5 ng/L benchmark cannot be checked.

EU legal limit
none detected sum of 20 PFAS below the detection limit, limit 100 ng/L
Last PFAS test
11 June 2025
Water supplier
C.C. TERRES TOULOISES

In Bouvron, none of the 4 most closely watched PFAS (PFAS-4) was detected at the latest PFAS check on 11 June 2025. The total is below 8 ng/L, the sum of the detection limits and 16 times our 0.5 ng/L benchmark. Sum of 20 PFAS: <0,005 µg/L, below the EU legal limit (100 ng/L). Source: Hub'eau, Qualité de l'eau potable (Ministère de la Santé / OFB / BRGM).

Details and sources
Water supplier: C.C. TERRES TOULOISES Latest water check: 24 July 2026 Data updated on

PFAS over time in Bouvron

A single PFAS check has been published for Bouvron so far (11 June 2025). A history will build up with the next checks; this page is refreshed weekly.

What the latest check found

At the latest check, the water was within every limit tested.

Microbiology: within the limit Chemistry: within the limit

Values to watch

These results are close to their legal limit, or over it.

Outside a reference value: Iron 1,200 µg/L on 24 July 2026 (reference ≤ 200 µg/L). These are indicator parameters with reference values, not legal limits.

What was tested Value Limit Status
Iron 1,200 µg/L ≤ 200 µg/L above the reference value
See all 17 test results
What was tested Value Limit Status
Nitrate <0,5 mg/L ≤ 50 mg/L within the limit
Nitrite <0,01 mg/L ≤ 0.5 mg/L within the limit
Arsenic 0.02 µg/L ≤ 10 µg/L within the limit
Cadmium <0,01 µg/L ≤ 5 µg/L within the limit
Chromium <0,05 µg/L ≤ 50 µg/L within the limit
Fluoride 0.72 mg/L ≤ 1.5 mg/L within the limit
Escherichia coli <1 n/(100mL) ≤ 0 mL) within the limit
Enterococci <1 n/(100mL) ≤ 0 mL) within the limit
Coliform bacteria <1 n/(100mL) ≤ 0 mL) within the limit
pH 7.3 unité pH 6.5–9 unité pH within the limit
Water hardness 33.6 °f no limit for reference
Electrical conductivity 680 µS/cm 200–1,100 µS/cm within the limit
Chloride 14 mg/L ≤ 250 mg/L within the limit
Sulphate 75 mg/L ≤ 250 mg/L within the limit
Sodium 10 mg/L ≤ 200 mg/L within the limit
Iron 1,200 µg/L ≤ 200 µg/L above the reference value
Turbidity 0.4 NFU ≤ 2 NFU within the limit

Frequently asked questions

Is tap water in Bouvron safe to drink?

Yes. At the check on 24 July 2026, the tap water in Bouvron was within every limit tested. Outside a reference value: Iron 1,200 µg/L on 24 July 2026 (reference ≤ 200 µg/L). These are indicator parameters with reference values, not legal limits. “Eau d'alimentation ne satisfaisant pas à la référence de qualité réglementaire pour le paramètre fer. Le fer n'entraîne pas directement un risque sanitaire mais il induit des effets indirects gênants pour l'usager, notamment une coloration rouille et des goûts perceptibles. Les mesures correctives nécessaires doivent être prises afin de rétablir la qualité de l'eau. Une analyse de recontrôle sera prochainement réalisée afin de vérifier le retour à une situation normale.”

How high are PFAS levels in Bouvron's drinking water?

At the latest check the total of 20 PFAS ("forever chemicals") was below the laboratory's reporting limit of 5 ng/L. The EU limit is 100 ng/L, so this water is under 5 % of the limit. (below the EU limit)

Does the water in Bouvron also meet the strictest limits in Europe?

The check cannot say. None of the four compounds was quantified, but the laboratory's detection limits add up to 8 ng/L, above Sweden's legal limit of 4 ng/L in force since 2026, so a value between the two would go unnoticed.

How hard is the water in Bouvron?

The water hardness in Bouvron is 33.6 °f (hard). This mainly matters for household appliances and detergent dosing, not for health.

Where does this data come from?

All values come from official publications: Hub'eau, Qualité de l'eau potable (Ministère de la Santé / OFB / BRGM). Retrieved on 21 September 2026.

Nearby communes

The closest to Bouvron on this site.

Data source

Hub'eau, Qualité de l'eau potable (Ministère de la Santé / OFB / BRGM)
https://hubeau.eaufrance.fr/api/v1/qualite_eau_potable/resultats_dis?code_commune=54088
License
Licence Ouverte / Open Licence (Etalab)
Retrieved
21 September 2026
Supply networks
BOUVRON

This site is a data project, not an official source. If in doubt, check with your water supplier or local authority.